Vai al contenuto principale della pagina
| Autore: |
Hayes Colin
|
| Titolo: |
Optimisation of corrosion control for lead in drinking water using computational modelling techniques / / Colin Hayes [and four others]
|
| Pubblicazione: | London, England : , : IWA Publishing, , [2013] |
| ©2013 | |
| Edizione: | 1st ed. |
| Descrizione fisica: | 1 online resource (67 p.) |
| Disciplina: | 628.168 |
| Soggetto topico: | Drinking water - Lead content - Data processing |
| Water - Purification - Lead removal | |
| Water-pipes - Corrosion - Data processing | |
| Note generali: | Description based upon print version of record. |
| Nota di bibliografia: | Includes bibliographical references. |
| Nota di contenuto: | ""Cover ""; ""Copyright""; ""Contents""; ""Foreword""; ""Acknowledgements""; ""Disclaimers""; ""Executive Summary""; ""Chapter 1: Introduction""; ""1.1 Corrective Water Treatment for Reducing Lead in Drinking Water""; ""1.2 Regulatory Background in the United States and the Need for Further Optimisation of Plumbosolvency Control""; ""1.3 Regulatory Background in Canada and the Need for Further Optimisation of Plumbosolvency Control""; ""1.4 Optimisation of Plumbosolvency Control in the United Kingdom and the Use of Computational Modelling Techniques"" |
| ""1.5 Project Outline, Objectives and Benefits""""Chapter 2: Description of the computational compliance models""; ""2.1 Introduction""; ""2.2 The Single Pipe Model""; ""2.3 The Zonal Modelling Framework""; ""2.4 Simulating Sampling""; ""Chapter 3: Simulation of water flow in a pipe using computational fluid dynamics""; ""3.1 Introduction""; ""3.2 The Fluid Flow Equations and their Computational Solution""; ""3.3 Comparison of Plug and Laminar Flow Along a Straight Pipe""; ""3.4 Application of Volumetric Profiles""; ""Chapter 4: Calibration and validation""; ""4.1 Introduction"" | |
| ""4.2 Calibration""""4.3 Validation""; ""Chapter 5: Case study: City A (US)""; ""5.1 Background""; ""5.2 Calibration and Use of the Lead Emission Model""; ""5.3 Results""; ""5.4 Discussion""; ""5.5 Conclusions""; ""Chapter 6: Case study: City B (CA)""; ""6.1 Background""; ""6.2 Calibration and Use of the Lead Emission Model""; ""6.3 Results""; ""6.4 Discussion""; ""6.5 Conclusions""; ""Chapter 7: Case study: City C (US)""; ""7.1 Background""; ""7.2 Assessment of Lead Data from Sequential Sampling Surveys""; ""7.3 Lead Service Lines and Plumbosolvency Characterisation""; ""7.4 Modelling"" | |
| ""7.5 Discussion""""7.6 Conclusions""; ""Chapter 8: Investigations into sequential sampling""; ""8.1 Introduction""; ""8.2 Sequential Sampling Surveys in Cities A, B and C""; ""8.3 Modelling Zonal Compliance""; ""8.4 Using Reynold�s Number""; ""8.5 Modelling Sequential Sampling at a Single House""; ""Chapter 9: Discussion""; ""9.1 The Use of Modelling in the Optimisation of Plumbosolvency Control""; ""9.2 Regulatory Aspects""; ""9.3 Operational Aspects""; ""9.4 Risk Assessment""; ""9.5 The Way Forward""; ""Chapter 10: Conclusions""; ""Chapter 11: References"" | |
| ""Appendix 1: Calibration data""""Appendix 2: Examples of model output"" | |
| Titolo autorizzato: | Optimisation of corrosion control for lead in drinking water using computational modelling techniques ![]() |
| ISBN: | 1-68015-564-4 |
| 1-78040-479-4 | |
| Formato: | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione: | Inglese |
| Record Nr.: | 9910811709003321 |
| Lo trovi qui: | Univ. Federico II |
| Opac: | Controlla la disponibilità qui |