Vai al contenuto principale della pagina

High-Flexion Knee Prosthesis : Design and Finite Element Analysis (FEA) / / by Iffa Mohd Arrif, Solehuddin Shuib, Amir Radzi Ab Ghani



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Arrif Iffa Mohd Visualizza persona
Titolo: High-Flexion Knee Prosthesis : Design and Finite Element Analysis (FEA) / / by Iffa Mohd Arrif, Solehuddin Shuib, Amir Radzi Ab Ghani Visualizza cluster
Pubblicazione: Singapore : , : Springer Nature Singapore : , : Imprint : Springer, , 2025
Edizione: 1st ed. 2025.
Descrizione fisica: 1 online resource (134 pages)
Disciplina: 610.153
Soggetto topico: Medical physics
Biomedical engineering
Mathematics - Data processing
Biomaterials
Medical Physics
Biomedical Engineering and Bioengineering
Computational Mathematics and Numerical Analysis
Altri autori: ShuibSolehuddin  
GhaniAmir Radzi Ab  
Nota di contenuto: Introduction -- Fundamental design and material of knee prosthesis.-Finite element analysis fea on knee prosthesis -- Development of high flexion tkr -- Finite element analysis fea and experimental -- Conclusion and recommendation.
Sommario/riassunto: This book highlights the design, modifications, and analysis of knee prosthesis or total knee replacement (TKR) components. CT scan images of a knee joint are extracted by 3D Gens. The model of knee joint is then developed to create 3D model structures using CAD software. The design modifications’ process focuses on the tibial insert component to increase the range of motion. All the design modifications were analyzed using FEA software. The book describes additive manufacturing (AM) in order to fabricate the TKR components using 3D printing techniques such as fused deposition modeling (FDM) and selective laser sintering (SLS). It uses FDM to print the tibial insert with polyamide material. Meanwhile, SLS prints the femoral and tibial components with titanium alloy material. TKR jigs were fabricated by advanced manufacturing process using stainless steel, and compression testing evaluated the deformation when the force is applied vertically to the femoral component. Compression testing results are not discussed as they were used to validate the results of FEA only. The outcomes of FEA were compared with the compression results in terms of deformation.
Titolo autorizzato: High-Flexion Knee Prosthesis  Visualizza cluster
ISBN: 981-9698-78-2
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9911031631903321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui
Serie: SpringerBriefs in Applied Sciences and Technology, . 2191-5318