Vai al contenuto principale della pagina

Focus for excellence laboratory practice / / Viroj Wiwanitkit



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Viroj Wiwanitkit Visualizza persona
Titolo: Focus for excellence laboratory practice / / Viroj Wiwanitkit Visualizza cluster
Pubblicazione: New York, : Nova Biomedical Books, c2009
Edizione: 1st ed.
Descrizione fisica: 1 online resource (130 p.)
Disciplina: 616.07/56
Soggetto topico: Diagnosis, Laboratory
Pathology
Note generali: Description based upon print version of record.
Nota di bibliografia: Includes bibliographical references and index.
Nota di contenuto: Intro -- FOCUS FOR EXCELLENCELABORATORY PRACTICE -- FOCUS FOR EXCELLENCELABORATORY PRACTICE -- Contents -- Preface -- Quality Process for LaboratoryAnalysis: Introduction -- Abstract -- What Is Quality in Laboratory Medicine? -- Quality Cycle in Laboratory Medicine -- Quality Control and Assurance -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- Example on Report on Result of CounselingUnit Service for Laboratory Medicine -- 1. Introduction -- 2. Materials and Methods -- 3. Result -- 4. Discussion -- Summary of Concept -- References -- Minimizing Errors in LaboratoryMedicine and Effect on Patient Care -- Abstract -- Introduction -- Natural History of Errorsin Laboratory Medicine -- 1. Epidemiology -- 2. Fade of Error -- Preanalytical Error -- Pre-Preanalytical Error -- Analytical Error -- Post-Preanalytical Error -- How to Manage the Problem of Error -- Effect of Laboratory ErrorControl on Patient Care -- References -- Developing Patient SafetyCulture in Clinical Laboratory -- Abstract -- Introduction -- 1.1. Specimen Collection -- 1.2. Transportation -- Conclusion -- References -- Quality Management:Example by ISO System -- Abstract -- Introduction -- Application of ISO for Medical Laboratory -- References -- Cost Study in Laboratory Medicine:Example -- Abstract -- Example 1: Comparative Study of the Cost-Effectiveness between Macroscopic Slide CellAgglutination and Microscopic AgglutinationTest for Diagnosis of Leptospirosis -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- 5. Conclusion -- Example 2: Cost Effective Analysisof Cultivation Method for Trichomoniasis -- 1. Basic Information on Trichnomoniasis -- 1.1. What Is the Importance of Trichomonas Vaginalis Infection? -- 1.2. Diagnosis for Trichomonas Vaginalis Infection -- 1.3. Culture Media for Trichomonas Vaginalis.
2. Materials and Methods -- 3. Results -- 4. Discussion -- References -- Problems of Phlebotomist -- Abstract -- Tuberculosis among the Phlebotomist,an Experience from Thailand -- A Case Study on Needle StickInjury on a Phlebotomist -- 1. Introduction -- 2. Case Study -- 3. Discussion -- Preventive Medicine for Venipuncture -- 1. General Information on Occupational Exposureto Blood Borne Pathogens [11 - 12] -- 2. Methods of Compliance [17] -- 2.4.1. Immediate First Aid -- 2.4.2. Report Incident -- References -- Interesting Aberration ofLaboratory Results: Case Stu -- Abstract -- Blood Group, Is It Still a SpecificLaboratory Result for Each Individual? -- 1. Introduction -- 2. Case Studies -- 3. Discussion -- A Case Study on Abnormal Low Activated PentialThromboplastin Result due for Analytical Error -- 1. Introduction -- 2. Case study -- 3. Discussion -- Problematic Cases in Clinical Chemistry inLaboratory Medicine -- Case Studiesof Total-Partial Determination -- 1. Introduction -- 2. Case studies -- 3. Discussion -- Problems with Low Density LipoproteinCholesterol (LDL-C) Determination:2 Case Studies -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- 5. Conclusion -- Interference Effect: Case Studies -- 1. Introduction -- 2. Cases -- 3. Discussion -- References -- Automation in Laboratory:What Are New Things? -- Abstract -- Introduction -- Autmation in Hematology: From ClassicalTechnology to Flow Cytometry -- Electrochemiluminescence: A New AnalyticalMean in Clinical Chemistry and Immunology [4] -- What Is the Future Trend of Automationin Medical Laboratory -- 1. Total Laboratory Automation -- 2. Point-of-Care Testing -- Monitoring of Lipid Profileby Bed-Side Device -- 1. Introduction to Lipid Profile Monitoring -- 2. Measurement of Lipid Profile in Clinical Laboratory.
3. Monitoring of Lipid Profile by Bed-Side Device -- Biochip: New Generation of Automation -- 1. Introduction -- 2. Developmental Process of a Biochip -- 3. Important New Types of Biochips -- Opinion Survey of Targeted Physicians forUsing of New Urinalysis Service by AutomatedAnalyzer, IQ-200: An Example -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- References -- Laboratory Information System:A Problematic Case Studies -- Abstract -- Introduction -- Case Studies -- Discussion -- Conclusion -- References -- Ethics in Laboratory Medicine:Some Aspects -- Abstract -- High Risk Laboratory Report:Problem and Prevention -- 1. Problem -- 2. Prevention -- Right Not to Know theInvestigation Result -- When a Medical Student Refuseto Get Procedure Training -- Violation on Medical Personnelin Laboratory: A Case Study -- 1. Introduction -- 2. Case Studies -- 3. Discussion -- Conflict of Interest -- 1. What Is Conflict of Interest? -- 2. Conflict of Interest in Medicine -- 3. Conflict of Interest in Laboratory Medicine -- References -- Urine Strip Examination, InterestingProblematic Cases inLaboratory Medicine -- Abstract -- Introduction -- Case Reports -- Discussion -- Reference -- Light Microscopy:Past, Property and Procedure -- Abstract -- Origin of Light Microscope:Past History [1-7] -- Important TechnicalProperties of LightMicroscope -- Light Microscope Procedure -- A. Examination Procedure -- B. Cleaning and Care of the Microscope -- References -- Concerns on Vacuum Tube -- Abstract -- Preanalytical Concerns on the Monosed-SR for the New Microsed-SR ErythrocyteSedimentation Rate Analyzer -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- Comparison between Evacuated Blood CollectionSystem and Classical System for ProthrombinTime Determination -- References.
Blood Glucose Determination inDiabetic Care: A Concernin Laboratory Medicine -- Abstract -- Introduction -- Dangers of PreanalyticalError on Diabetes Care -- A. Errors in Patient Preparation -- B. Errors in Patient Identification -- C. Errors due to Wrong Specimen Additivesand Order of Collected Sample -- D. Errors in Specimen Transportation -- E. Errors due to Biological Variability -- How to Control the Preanalytical Errorin Diabetic Laboratory Investigation -- A Case Study on Pre-Analytical FactorInterference for Oral Glucose Tolerance Test -- A Conceptual Study on the Effect of PoorControlled Diabetes Defined by Hemoglobin A1CTest via Hemoglobin Cranston Model -- 1. Introduction -- 2. Materials and Methods -- 3. Results -- 4. Discussion -- References -- Index.
Sommario/riassunto: Laboratory Investigation is a big tool for biological and medical work around the world. The present concept of laboratory investigation is to provide the best analysis. This covers several facets and all phases of the laboratory cycle. In this book, concept and scenarios on excellent laboratory practice will be discussed and presented.
Titolo autorizzato: Focus for excellence laboratory practice  Visualizza cluster
ISBN: 1-60741-413-9
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9910955649203321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui