Electrical installations in hazardous areas / / Alan McMillan
| Electrical installations in hazardous areas / / Alan McMillan |
| Autore | McMillan Alan |
| Pubbl/distr/stampa | Boston, : Butterworth-Heinemann, 1998 |
| Descrizione fisica | 1 online resource (669 p.) |
| Disciplina |
363.189
621.31/042/0289 21 621.310420289 |
| Soggetto topico |
Explosionproof electric apparatus and appliances
Electric apparatus and appliances - Safety measures Hazardous substances - Safety measures |
| ISBN |
1-281-03922-5
9786611039226 0-08-052355-2 |
| Formato | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione | eng |
| Nota di contenuto |
Front Cover; Electrical Installations in Hazardous Areas; Copyright Page; Contents; Preface; Chapter 1. Introduction; 1.1 Examples of historic incidents; 1.2 Technological approach; 1.3 History of development; 1.4 UK legislation; 1.5 European legislation; 1.6 Certification; 1.7 Certificate and labelling information; 1.8 The future of certification; Chapter 2. Area classification; Philosophy objectives and procedures; 2.1 Basic properties of flammable and combustible materials; 2.2 Basis of area classification; 2.3 General approach to area classification
2.4 Classification of sources of release2.5 Hazardous zonal classification; 2.6 Collection of information; 2.7 Procedures; 2.8 Personnel involved; 2.9 Results of area classification and frequency of repeats; Chapter 3. Area classification practice for gases, vapours and mists in freely ventilated situations; Introduction; 3.1 Containment of flammable materials; 3.2 Generalized method of area classification; 3.3 The source of hazard method of area classification; 3.4 Other practical well-ventilated situations; Chapter 4. Calculation of release rates and the extents of hazardous areas 4.1 Releases of gas and vapour4.2 Release of liquid below its atmospheric boiling point; 4.3 Release of liquid above its atmospheric boiling point; 4.4 Summary of use of equations; 4. 5 Releases in areas which are not well ventilated; 4.6 Conclusion; Chapter 5. Area classification practice for gases, vapours and mists in areas which are not freely ventilated; 5.1 Typical areas of restricted ventilation; 5.2 Effect of walls on hazardous areas; 5.3 Roofs without walls or associated with one, two or three walls; 5.4 Rooms above ground; 5.5 Rooms below ground 5.6 Rooms without any internal release but which abut external hazardous areas5.7 Particular circumstances; Chapter 6. Area classification practice for dusts; 6.1 Properties of dusts; 6.2 Area classification for dust releases; 6.3 Practical situations; Chapter 7. Design philosophy for electrical apparatus for explosive atmospheres; General approach and applicable standards; 7.1 History; 7.2 Protection of electrical apparatus for gas, vapour and mist risks; 7.3 Situation in respect of Zone 2 apparatus; 7.4 Protection of electrical apparatus for dust risks; 7.5 Apparatus construction Standards Chapter 8. General requirements for explosion protected apparatus (gas, vapour and mist risks)Apparatus to European Standards; 8.1 BS/EN 50014 (1993) (including amendment 1 (1994)); Chapter 9. Apparatus using protection concepts encapsulation 'm', oil immersion 'o' and powder filling 'q'; 9.1 Encapsulation -'m'; 9.2 Oil immersion -'o'; 9.3 Powder filling -'q'; Chapter 10. Apparatus using protection concept flameproof enclosure 'd'; 10.1 Standards for flameproof apparatus; 10.2 Construction and testing requirements for flamepaths 10.3 Construction of flameproof enclosures, entry facilities and component parts |
| Record Nr. | UNINA-9911006834803321 |
McMillan Alan
|
||
| Boston, : Butterworth-Heinemann, 1998 | ||
| Lo trovi qui: Univ. Federico II | ||
| ||
Explosion protection [e-book] : electrical apparatus and systems for chemical plants, oil and gas industry, coal mining / Heinrich Groh
| Explosion protection [e-book] : electrical apparatus and systems for chemical plants, oil and gas industry, coal mining / Heinrich Groh |
| Autore | Groh, Heinrich |
| Pubbl/distr/stampa | Amsterdam ; Boston : Elsevier/Butterworth Heinemann, 2004 |
| Descrizione fisica | xv, 524 p. : ill. ; 24 cm |
| Disciplina | 628.922 |
| Soggetto topico |
Mine gases
Firedamp Explosions - Safety measures Explosionproof electric apparatus and appliances Chemical plants - Safety measures |
| Soggetto genere / forma | Electronic books. |
| ISBN |
9780750647779
0750647779 |
| Formato | Risorse elettroniche |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione | eng |
| Nota di contenuto | Basic principles of explosion protection. -- The classification of hazardous areas. -- Standards for electrical apparatus and systems in Zone 1. -- Grouping and classification of explosion protected electrical apparatus. -- Marking and selection of explosion protected apparatus. -- The different types of protection - constructional requirements. -- Analyzers and analyzer rooms. -- Testing explosion protected electrical equipment. -- Financial considerations - selecting explosion protected electrical equipment. -- Inspection, maintenance and repair of explosion protected equipment. -- Explosion protected apparatus for Zone 0 and Zone 2. -- Cable protection in coal mines and other areas hazardous due to combustibles. -- Bibliography. -- Index |
| Record Nr. | UNISALENTO-991003228799707536 |
Groh, Heinrich
|
||
| Amsterdam ; Boston : Elsevier/Butterworth Heinemann, 2004 | ||
| Lo trovi qui: Univ. del Salento | ||
| ||