Loft conversions [[electronic resource] /] / John Coutts
| Loft conversions [[electronic resource] /] / John Coutts |
| Autore | Coutts John <1965-> |
| Edizione | [2nd ed.] |
| Pubbl/distr/stampa | Chichester, West Sussex, U.K. ; ; Ames, Iowa, : Wiley-Blackwell, 2013 |
| Descrizione fisica | 1 online resource (292 p.) |
| Disciplina |
690.83
728.314 728/.314 |
| Soggetto topico | Lofts - Remodeling for other use |
| Soggetto genere / forma | Electronic books. |
| ISBN |
1-118-39998-6
1-299-18127-9 1-118-40001-1 1-118-40002-X |
| Formato | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione | eng |
| Nota di contenuto |
Loft Conversions; Copyright; Contents; Preface; Acknowledgements; 1 Planning and legal considerations; Permitted development; Permitted development law; Commentary on permitted development provisions - England; Permitted development restrictions; Curtilage: raising party walls; Conservation areas; Article IV directions; Planning conditions affecting permitted development; Listed buildings; Other conditions affecting development; Restrictive covenants; Mortgage lenders; Buildings and contents insurance; Tree preservation orders; Bats; Lawful Development Certificate; Planning permission
Planning applicationsSources of planning guidance; Supplementary planning guidance; Supplementary planning documents; Design guides; Design codes; Local Development Framework; Unitary Development Plan; The Party Wall etc. Act 1996; Procedure; Disputes; 2 The Building Regulations and building control; The Building Act 1984; The Building Regulations; Approved Document guidance; Compliance guides; Relationship between the Building Regulations and the Approved Documents; Building control; Local authority building control; Full plans; Building notice; Notification and inspection of work Resolving Building Regulations disputesElectronic building control applications; Approved inspector building control; 3 External forms; Primary influences on form; Planning considerations; Pitch, plan and headroom; Stair access; Shallow-pitched roofs; Existing roof type; Conversion forms; Roof space only conversion; Box dormer conversion; Front box dormer conversion; Hip-to-gable conversion; Side dormer conversion; Full-width dormer with masonry flanks; Mansard conversion; Lean-to conversion; Half dormer; Existing attic rooms; Galleries and platforms; Traditional dormer forms; Gabled dormer Hipped dormerFlat dormer (small); Cat slide dormer; Recessed dormer; Eyebrow dormer; Arched dormer; Segmental dormer; Pedimented dormer; Canted bay dormer; Design considerations; Fenestration; Roof detail; Vertical cladding and roofing materials; Chimney positions; Drainage; 4 Fire safety; Regulatory framework; Main changes to Approved Document B (2006); Fire resistance: basic requirements; Warning and escape; Floor height rules; Storey and floor numbering rules; Fire safety: common configurations - Floor not more than 4.5m above lowest ground level; Means of warning; Means of escape One floor more than 4.5m above ground levelMeans of warning; First floor fire resistance; New floor (conversion); Escape windows; Means of escape; More than one floor over 4.5m above ground level; Galleries; Elements and terminology; Access room; AFD; Air circulation systems; Alternative escape route; Automatic self-closing devices (self closers); Balconies and flat roofs; Cavity barriers; Doors - glazing in final exit; Emergency egress (escape) windows and external doors; Escape route; Final exit; Fire curtains; Fire detection and fire alarm systems; Fire doors Fire stopping and the protection of openings |
| Record Nr. | UNINA-9910141485003321 |
Coutts John <1965->
|
||
| Chichester, West Sussex, U.K. ; ; Ames, Iowa, : Wiley-Blackwell, 2013 | ||
| Lo trovi qui: Univ. Federico II | ||
| ||
Loft conversions [[electronic resource] /] / John Coutts
| Loft conversions [[electronic resource] /] / John Coutts |
| Autore | Coutts John <1965-> |
| Edizione | [2nd ed.] |
| Pubbl/distr/stampa | Chichester, West Sussex, U.K. ; ; Ames, Iowa, : Wiley-Blackwell, 2013 |
| Descrizione fisica | 1 online resource (292 p.) |
| Disciplina |
690.83
728.314 728/.314 |
| Soggetto topico | Lofts - Remodeling for other use |
| ISBN |
1-118-39998-6
1-299-18127-9 1-118-40001-1 1-118-40002-X |
| Formato | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione | eng |
| Nota di contenuto |
Loft Conversions; Copyright; Contents; Preface; Acknowledgements; 1 Planning and legal considerations; Permitted development; Permitted development law; Commentary on permitted development provisions - England; Permitted development restrictions; Curtilage: raising party walls; Conservation areas; Article IV directions; Planning conditions affecting permitted development; Listed buildings; Other conditions affecting development; Restrictive covenants; Mortgage lenders; Buildings and contents insurance; Tree preservation orders; Bats; Lawful Development Certificate; Planning permission
Planning applicationsSources of planning guidance; Supplementary planning guidance; Supplementary planning documents; Design guides; Design codes; Local Development Framework; Unitary Development Plan; The Party Wall etc. Act 1996; Procedure; Disputes; 2 The Building Regulations and building control; The Building Act 1984; The Building Regulations; Approved Document guidance; Compliance guides; Relationship between the Building Regulations and the Approved Documents; Building control; Local authority building control; Full plans; Building notice; Notification and inspection of work Resolving Building Regulations disputesElectronic building control applications; Approved inspector building control; 3 External forms; Primary influences on form; Planning considerations; Pitch, plan and headroom; Stair access; Shallow-pitched roofs; Existing roof type; Conversion forms; Roof space only conversion; Box dormer conversion; Front box dormer conversion; Hip-to-gable conversion; Side dormer conversion; Full-width dormer with masonry flanks; Mansard conversion; Lean-to conversion; Half dormer; Existing attic rooms; Galleries and platforms; Traditional dormer forms; Gabled dormer Hipped dormerFlat dormer (small); Cat slide dormer; Recessed dormer; Eyebrow dormer; Arched dormer; Segmental dormer; Pedimented dormer; Canted bay dormer; Design considerations; Fenestration; Roof detail; Vertical cladding and roofing materials; Chimney positions; Drainage; 4 Fire safety; Regulatory framework; Main changes to Approved Document B (2006); Fire resistance: basic requirements; Warning and escape; Floor height rules; Storey and floor numbering rules; Fire safety: common configurations - Floor not more than 4.5m above lowest ground level; Means of warning; Means of escape One floor more than 4.5m above ground levelMeans of warning; First floor fire resistance; New floor (conversion); Escape windows; Means of escape; More than one floor over 4.5m above ground level; Galleries; Elements and terminology; Access room; AFD; Air circulation systems; Alternative escape route; Automatic self-closing devices (self closers); Balconies and flat roofs; Cavity barriers; Doors - glazing in final exit; Emergency egress (escape) windows and external doors; Escape route; Final exit; Fire curtains; Fire detection and fire alarm systems; Fire doors Fire stopping and the protection of openings |
| Record Nr. | UNINA-9910830138103321 |
Coutts John <1965->
|
||
| Chichester, West Sussex, U.K. ; ; Ames, Iowa, : Wiley-Blackwell, 2013 | ||
| Lo trovi qui: Univ. Federico II | ||
| ||
Symposium on Some Approaches to Durability in Structures
| Symposium on Some Approaches to Durability in Structures |
| Pubbl/distr/stampa | [Place of publication not identified], : American Society for Testing & Materials, 1958 |
| Descrizione fisica | 1 online resource (67 pages) : illustrations |
| Disciplina | 690.83 |
| Collana | ASTM special technical publication |
| Soggetto topico | Building |
| ISBN | 0-8031-5624-3 |
| Formato | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione | eng |
| Record Nr. | UNINA-9910164261003321 |
| [Place of publication not identified], : American Society for Testing & Materials, 1958 | ||
| Lo trovi qui: Univ. Federico II | ||
| ||