Vai al contenuto principale della pagina

8th International Conference on the Development of Biomedical Engineering in Vietnam : Proceedings of BME 8, 2020, Vietnam: Healthcare Technology for Smart City in Low- and Middle-Income Countries



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Van Toi Vo Visualizza persona
Titolo: 8th International Conference on the Development of Biomedical Engineering in Vietnam : Proceedings of BME 8, 2020, Vietnam: Healthcare Technology for Smart City in Low- and Middle-Income Countries Visualizza cluster
Pubblicazione: Cham : , : Springer International Publishing AG, , 2021
©2022
Descrizione fisica: 1 online resource (1042 pages)
Soggetto genere / forma: Electronic books.
Altri autori: NguyenThi-Hiep  
LongVong Binh  
HuongHa Thi Thanh  
Nota di contenuto: Intro -- Preface -- Contents -- Medical Instrumentations -- Device to Detect Acupuncture Points in the Feet Soles for Massage Treatment -- 1 Introduction -- 2 Related Works -- 3 Hardware Platform -- 3.1 Sensor Max30100 -- 3.2 Vibration Motor -- 4 Acupressure Detection Method -- 4.1 Principle of Measuring SpO2 -- 4.2 Algorithms for Acupuncture Points -- 5 Experimental Setup and Results -- 5.1 Experimental Setup -- 5.2 Accuracy Verification Methods -- 6 Conclusion -- References -- Wireless Heart Rate Monitoring Using Sound Sensor -- 1 Introduction -- 2 Background and Related Work -- 3 A Design for Wireless Heart Rate Monitoring -- 3.1 Doctor's Side for Monitoring the Heart Rate -- 3.2 Patient's Side with the Sound Sensor -- 3.3 Wireless RF Module for Communication -- 4 A Prototype for Heart Rate Monitoring -- 4.1 The Amplifier and the Sound Sensor -- 4.2 The MCU -- 4.3 The RF Module -- 5 Measurement Method -- 5.1 Scheme for Measuring the Heart Rate -- 5.2 Amplifying and Sampling the Sound of the Heart -- 5.3 Counting and Display the Heartbeat -- 6 Experimental Results -- 6.1 Experimental Setup -- 6.2 Result -- 7 Conclusion and Future Work -- References -- Equipment for Contact-Free Respiratory Measurement and Obstructive Sleep Apnea Detection -- 1 Introduction -- 2 Related Work -- 3 Hardware Platform -- 4 Respiratory Rate Counting and Sleep Apnea Detecting Method -- 4.1 Calculating Real Distance Values -- 4.2 Algorithms for Measuring Respiratory Rate and Detecting Sleep Apnea -- 5 Experimental Setup and Results -- 5.1 Experimental Setup -- 5.2 Results -- 6 Conclusion -- References -- Non-invasive Pressure Support Ventilator for Patients with Respiratory Failure in Under Resourced Regions -- 1 Introduction -- 2 General Description of the Device -- 3 Ventilator Components, Data Processing and Control -- 3.1 Blower -- 3.2 Pressure Transducers.
3.3 Flow Measurement -- 3.4 Microcontroller -- 3.5 Operator Interface -- 3.6 Ventilator State Control -- 4 Suitability of the Ventilator for Low Resource Regions -- 5 Conclusions -- References -- Implementation of a Drum Collector for Electrospinning Machines Based on Embedded System -- 1 Introduction -- 1.1 The Artificial Approach to Cure Wound Healing -- 1.2 The Principal of Electrospinning Machines -- 2 Designing of a Drum Collector for the Electrospinning Machine Mechanical Design -- 2.1 Mechanical Design -- 2.2 Hardware Development -- 3 Methodology -- 4 Result of Experiment -- 4.1 Optimized Parameters -- 4.2 Morphology Analysis -- 4.3 Membranes Under SEM Image Observation -- 5 Conclusion -- References -- Development of a Low-Cost and Portable Real-Time PCR Machine for Developing Countries -- 1 Introduction -- 2 Related Works -- 3 Materials and Methods -- 3.1 Thermocycler -- 3.2 Optical System -- 3.3 Heat Lid -- 4 Results and Discussion -- 4.1 Fluorescence Acquisition System -- 4.2 Temperature Control -- 4.3 Optical Setup -- 4.4 Real-Time PCR -- 5 Conclusions -- References -- Design and Fabrication of a Complete Electrospinning System -- 1 Introduction -- 1.1 Some Methods to Treat Wound Healing -- 1.2 Basic Component of Electrospinning Machines -- 2 Design an Electrospinning System Consists of a Fume Hood Controller -- 2.1 Mechanical Design -- 2.2 Hardware Development -- 3 Firmware Development -- 3.1 The Operation of the Control Panel Board -- 3.2 The Description of How the Main Board Control Operated -- 3.3 The Control Syringe Pump and Slider Procedures -- 4 Result of Experiment -- 4.1 Testing Methodology -- 5 Conclusion -- References -- Design of a Soft Robotic Glove for Hand Rehabilitation Based on Pneumatic Network Method and Low Cost Electro-pneumatic Device -- 1 Introduction -- 2 Related Work -- 3 Methods -- 3.1 Design Elastomeric Materials.
3.2 Electro-pneumatic Design -- 3.3 Pressure Sensor Calibration -- 4 Experimental Test and Results -- 4.1 Electro-pneumatic System -- 4.2 Force Measurement -- 4.3 Grasping of Objects of Various Shapes -- 5 Conclusion and Future Works -- References -- Portable Hand Vein Finder System Based on Near-Infrared Illumination and Morphological Image Processing -- 1 Introduction -- 2 Materials and Methods -- 2.1 Principle of Near-Infrared Imaging in Vein Finder -- 2.2 Main Components of a Portable Vein Finder Prototype -- 3 Results and Discussion -- 3.1 Image Processing for Displaying on a Monitor -- 3.2 Image Processing for Projecting the Venous Patterns on the Skin -- 3.3 Design of a Portable Vein Finder Prototype -- 3.4 Portable Vein Finder Prototype -- 4 Conclusion -- References -- Applying Soft Actuator Technology for Hand Rehabilitation -- 1 Introduction -- 2 Materials and Design -- 2.1 Materials -- 2.2 Soft Pneumatic Actuator -- 3 Results and Discussion -- 3.1 Mold Design -- 3.2 Simulation and Actual Results -- 3.3 Glove Design for Hand Rehabilitation -- 4 Conclusion -- References -- Design of an Automatic System for Bioelectrical Impedance Phase Angle Measurement Using an Analog Multiplier -- 1 Introduction -- 2 Methods and Materials -- 2.1 Electrode Method -- 2.2 Power Supply -- 2.3 Current Source -- 2.4 Instrumentation Amplifier -- 2.5 Bioelectrical Impedance Phase Angle Measurement Unit -- 3 Results and Discussion -- 3.1 Assessment of the Sine-Wave Generator Using AD9833 -- 3.2 Assessment of the Current Source -- 3.3 Assessment of the Phase Angle Measuring Unit -- 4 Conclusion -- References -- Smart Blind Stick for Visually Impaired People -- 1 Introduction -- 2 Materials and Methods -- 2.1 Stick Construction -- 2.2 Obstacle Detection and Alarming System -- 2.3 Data Transmission -- 2.4 Power Source -- 3 Results and Discussions.
3.1 Testing Procedure -- 3.2 Obstacle Detection Experiment -- 3.3 Data Transmission Experiment -- 4 Conclusion -- References -- Biomechanics -- A Study of Polishing Parameters to Surface Roughness of Magnetorheological Polishing Methods -- 1 Introduction -- 2 Principle of MRP -- 3 Experimental Setup -- 4 Results and Discussion -- 4.1 Effect of Polishing Speed -- 4.2 Effect of Abrasive Sizes -- 4.3 Effect of Electric Current -- 5 Conclusions -- References -- Effect of Applied Load and Surface Texture on Friction of UHMWPE in Total Joint Replacement -- 1 Introduction -- 2 Materials and Methods -- 2.1 Preparation of Specimens -- 2.2 Preparation of 25 mg/ml BSA -- 2.3 Frictional Testing Apparatus and Procedure -- 2.4 Data Analyses -- 3 Results and Discussion -- 3.1 Effect of Applied Load on Friction of UHMWPE -- 3.2 Effect of Surface Texture on Friction of UHMWPE -- 4 Conclusions -- References -- An Automatic Control System for Measuring Stokes Polarization and Utilizing UV Light Source -- 1 Introduction -- 2 Methods -- 2.1 Methodology -- 2.2 Hardware Design -- 2.3 Firmware and Software Development -- 3 Results and Discussion -- 3.1 Designed Hardware -- 3.2 Validation for Accuracy of the System -- 4 Conclusion -- References -- A Statistical Approach to Evaluate Beta Response in Motor Imagery-Based Brain-Computer Interface -- 1 Introduction -- 2 Methodology -- 2.1 Subjects and Environment -- 2.2 Data Acquisition -- 2.3 Experiment Paradigm -- 3 Data Processing -- 4 Results and Discussion -- 4.1 Temporal Relative Power Plot -- 4.2 Beta Response During Motor Imagery -- 4.3 Characteristic Frequency Band During Motor Imagery -- 5 Conclusion -- References -- Internet of Things and Telemedicine -- A New Design of an Automated System to Collect and Monitor Temperature and Humidity -- 1 Introduction -- 2 Experimental Design -- 2.1 System Design.
2.2 Hardware Design -- 2.3 Software Implementation -- 3 Result and Discussion -- 3.1 Experimental Result -- 3.2 Discussion -- 4 Conclusion -- References -- Design of NIBP Holter System Based on NIBP Device and Smartphone -- 1 Introduction -- 2 Design System -- 2.1 Principle Diagram Design -- 2.2 iChoice BP1 Device -- 2.3 Design the App for Patient -- 2.4 Design the App for Doctor -- 2.5 Design the Database -- 3 Designing and Testing Results -- 3.1 Designing Result -- 3.2 Testing Result -- 4 Conclusions -- References -- Research and Design of Braille Learning Aids for Visually Impaired People Applying IoT Technology -- 1 Introduction -- 2 Design System -- 3 System Modes and IoT Technology Applications -- 4 Experiment and Evaluate the Results -- References -- Internet of Things Application for Online Surveillance and Control of Attacks by Sea Lice -- 1 Introduction -- 2 Materials and Methods -- 2.1 Electronic Module -- 2.2 Microfluidic Module -- 2.3 Process Flow -- 2.4 Water Sample Preparation -- 3 Results and Discussion -- 4 Conclusion -- References -- Efficiency Evaluation of a Pilot Telemedicine System to Monitor High Blood Pressures in Binh Duong Province (Vietnam) -- 1 Introduction -- 2 Materials and Method -- 2.1 The Tele-blood Pressure Device -- 2.2 The Cloud Telemedicine Information System (CTIS) -- 2.3 The Patients Section Process for the Study -- 2.4 Clinical Monitoring Process -- 2.5 Users Survey -- 3 Results -- 3.1 Characteristics of Participants in 2 Groups -- 3.2 Comparison of the Results of the Two Research Groups at Each Study Time -- 3.3 Subclinical Results -- 3.4 Evaluate the Effectiveness of Health Care in the Performance of the Telemedicine System -- 4 Conclusions -- References -- Pharmaceutical Engineering and Nanomaterials in Medical Applications.
Improvement of Curcumin Solubility and Bioactivities by the Designed Redox Nanoparticles.
Altri titoli varianti: 8th International Conference on the Development of Biomedical Engineering in Vietnam
Titolo autorizzato: 8th International Conference on the Development of Biomedical Engineering in Vietnam  Visualizza cluster
ISBN: 3-030-75506-1
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9910497101903321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui
Serie: IFMBE Proceedings Ser.