Vai al contenuto principale della pagina
| Autore: |
Manap Muhammad Faris bin Abd
|
| Titolo: |
Total Hip Replacement (THR) : Effect of Inclination and Anteversion Angle on the Performance of Epoxy-UHMWPE Acetabular Cup / / by Muhammad Faris bin Abd Manap, Solehuddin Shuib, Ahmad Zafir Romli
|
| Pubblicazione: | Singapore : , : Springer Nature Singapore : , : Imprint : Springer, , 2024 |
| Edizione: | 1st ed. 2024. |
| Descrizione fisica: | 1 online resource (116 pages) |
| Disciplina: | 610.153 |
| Soggetto topico: | Medical physics |
| Biomedical engineering | |
| Biomechanics | |
| Biomaterials | |
| Mathematics - Data processing | |
| Medical Physics | |
| Biomechanical Analysis and Modeling | |
| Computational Mathematics and Numerical Analysis | |
| Biomedical Engineering and Bioengineering | |
| Altri autori: |
ShuibSolehuddin
RomliAhmad Zafir
|
| Nota di contenuto: | Chapter 1. THE EFFECT OF INCLINATION AND ANTEVERSION ANGLE ON THE PERFORMANCE OF EPOXY-UHMWPE ACETABULAR CUP -- Chapter 2. METAL-ON-METAL TOTAL HIP REPLACEMENT AND SAFE ZONE ORIENTATION OF ACETABULAR CUP -- Chapter 3. FINITE ELEMENT ANALYSIS (FEA) OF METAL-ON-POLYMER (MoP) AND ACETABULAR CUP MATERIAL -- Chapter 4. NUMERICAL AND MATHEMATICAL MODELLING FOR ACETABULAR CUP ORIENTATION -- Chapter 5. EXPERIMENTAL WORK OF EPOXY-UHMWPE MATERIALS -- Chapter 6. ANALYTICAL RESULTS OF SAFE ZONE ORIENTATION -- Chapter 7. FINITE ELEMENT ANALYSIS (FEA) STATIC STRUCTURAL ANALYSIS -- Chapter 8. EXPERIMENTAL WORK OF EPUHMWPE MATERIALS -- Chapter 9. THE PERFORMANCE OF EPOXY-UHMWPE AT DIFFERENT INCLINATION AND ANTEVERSION ANGLE. |
| Sommario/riassunto: | This book highlights the critical challenges faced in total hip replacement (THR) procedures, particularly concerning the performance and longevity of acetabular components. Despite advancements in implant technology, issues such as improper orientation and material failure continue to result in complications, including dislocation and wear. Recognizing the need for more reliable solutions, this book explores the optimization of safe zone orientation and the development of composite materials, specifically focusing on metal-on-polymer (MoP) implants. By investigating these factors through numerical analysis, finite element analysis (FEA), and experimental studies, the book seeks to enhance implant performance, reduce failure rates, and ultimately improve patient outcomes in THR surgeries. |
| Titolo autorizzato: | Total Hip Replacement (THR) ![]() |
| ISBN: | 9789819609758 |
| 9819609755 | |
| Formato: | Materiale a stampa |
| Livello bibliografico | Monografia |
| Lingua di pubblicazione: | Inglese |
| Record Nr.: | 9910951901403321 |
| Lo trovi qui: | Univ. Federico II |
| Opac: | Controlla la disponibilità qui |