Vai al contenuto principale della pagina

Advances in Digital Health and Medical Bioengineering : Proceedings of the 11th International Conference on E-Health and Bioengineering, EHB-2023, November 9–10, 2023, Bucharest, Romania – Volume 1: Medical Devices, Measurements, and Artificial Intelligence Applications / / edited by Hariton-Nicolae Costin, Ratko Magjarević, Gladiola Gabriela Petroiu



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Costin Hariton-Nicolae Visualizza persona
Titolo: Advances in Digital Health and Medical Bioengineering : Proceedings of the 11th International Conference on E-Health and Bioengineering, EHB-2023, November 9–10, 2023, Bucharest, Romania – Volume 1: Medical Devices, Measurements, and Artificial Intelligence Applications / / edited by Hariton-Nicolae Costin, Ratko Magjarević, Gladiola Gabriela Petroiu Visualizza cluster
Pubblicazione: Cham : , : Springer Nature Switzerland : , : Imprint : Springer, , 2024
Edizione: 1st ed. 2024.
Descrizione fisica: 1 online resource (849 pages)
Disciplina: 610.28
Soggetto topico: Biomedical engineering
Machine learning
Signal processing
Medical informatics
Biomedical Devices and Instrumentation
Machine Learning
Signal, Speech and Image Processing
Health Informatics
Altri autori: MagjarevićRatko  
PetroiuGladiola Gabriela  
Nota di contenuto: Intro -- Preface -- Organization -- Contents -- Medical Devices, Instrumentation, and Measurements -- Optimizing Magnetic Fields and Coil Designs for Magnetic Hyperthermia - Breast Cancer Treatment -- 1 Introduction -- 2 Database and Methods -- 2.1 Aims and Objectives -- 2.2 Conditions to Be Considered -- 2.3 Methods and Simulation -- 3 Results -- 4 Conclusions -- References -- Using LabVIEW in Neural Network Modeling -- 1 Introduction -- 2 Related Works -- 3 Experimental Study -- 3.1 Methodology of Cybersemiotic Modeling in LabVIEW -- 3.2 Cybersemiotic Model Structure -- 4 Conclusions -- References -- Comparing Perfusion Index Between Fingers During Short-Term Hypoxemia: Implications for SpO2 Monitoring -- 1 Introduction -- 2 Methods -- 2.1 Study Group -- 2.2 Interventions -- 2.3 Statistical Analysis -- 3 Results -- 4 Discussion -- 5 Conclusion -- References -- Group Delay Effect Analysis Between Arterial Blood Pressure and Photoplethysmography Waveforms -- 1 Introduction -- 2 Database and Methods -- 2.1 Signals Acquisition -- 2.2 Measurement Method -- 3 Results -- 4 Conclusions -- References -- Considerations for Controlling a Bionic Hand Using EMG Sensors -- 1 Introduction -- 2 Database and Methods -- 2.1 The Bionic Hand Controlled via Accelerometers -- 2.2 The Bionic Hand Controlled by Means of Myoelectric Signals -- 3 Results -- 4 Conclusions -- References -- Cloud Anchors-Based Localization in a Navigation System for Visually Impaired People -- 1 Introduction -- 2 Related Work -- 2.1 Navigation Systems for VIP -- 2.2 Cloud Anchors-Based Localization -- 3 System Requirements and Architecture -- 3.1 System Requirements -- 3.2 System Architecture -- 4 Evaluation of the Localization Solution -- 4.1 Evaluation of the Localization with One Cloud Anchor -- 4.2 Evaluation of the Localization with Multiple Cloud Anchors.
4.3 Rendering the User's Position on a Virtual 2D Map -- 5 Conclusions -- References -- Electronic Phantom for Wall Shear Rate Emulation -- 1 Introduction -- 2 The Electronic Phantom for WSR -- 2.1 The Signal Model -- 2.2 The Hardware -- 3 Experiments -- 3.1 Experimental Set-Up -- 3.2 Results -- 4 Conclusion -- References -- Comparison of Wrist Positions and Assessment Techniques to Evaluate Disynaptic Group I Inhibition -- 1 Introduction -- 2 Materials and Methods -- 2.1 Participants -- 2.2 Experimental Protocol -- 2.3 Data Analysis -- 2.4 Statistical Analysis -- 3 Results -- 3.1 H-Reflex Conditioning-Test Paradigm -- 3.2 Modulation of On-Going EMG -- 4 Discussion and Conclusions -- References -- Flexible Self-Poled P(VDF-TrFE)/SnO2 Composite Piezoelectric Film for Energy Harvesting and Wearable Sensors -- 1 Introduction -- 2 Experimental Details -- 3 Results and Discussions -- 4 Conclusion -- References -- Assessment of Different Biosignals with Potential Benefits in Robotic Assisted Neuromotor Rehabilitation -- 1 Introduction -- 2 Current and Future Trends in Robotic Rehabilitation -- 3 Future-Proofing Robotic Rehabilitation: Integration Strategies -- 3.1 Biosignals of Interest in the Medical Rehabilitation of Patients with Neuromotor Deficit -- 3.2 Adaptable Intelligent Algorithms -- 3.3 Critical Elements in Biosignal Monitoring -- 4 Discussion and Conclusions -- References -- DNN Surrogate Towards Fast Ablation Zone Prediction in Thermal Ablation -- 1 Introduction -- 2 Models and Methods -- 2.1 PDE Model -- 2.2 DNN Model: Feasibility Test Case for Performance Speed up -- 3 Results -- 4 Outlook and Conclusion -- References -- Creation of Physical Breast Phantom for Educational Purposes -- 1 Introduction -- 2 Materials and Methods -- 2.1 Computational Model -- 2.2 Physical Model -- 2.3 Mammography Unit and Imaging Protocols -- 3 Results.
4 Conclusions -- References -- Overview of Non-invasive Blood Glucose Measurement Techniques -- 1 Introduction -- 2 Database and Methods -- 3 Basic Measuring Methods -- 3.1 Spectroscopy -- 3.2 Optical Coherence Tomography -- 3.3 Photoplethysmography -- 4 Results -- 4.1 Infrared Spectroscopy -- 4.2 Raman Spectroscopy -- 4.3 Optical Coherence Spectroscopy -- 4.4 Photoplethysmography -- 4.5 Photoacoustic Measurements -- 4.6 Electrochemical Measurements -- 4.7 Bioimpedance Measurements -- 5 Discussion -- 6 Conclusions -- References -- Review of Non-Invasive Analysis of Blood Components -- 1 Introduction -- 2 Methodology -- 3 Current Research in Blood Analysis -- 3.1 Cholesterol -- 3.2 Hemoglobin -- 3.3 Troponin -- 3.4 Multi-component Analysis -- 4 Discussion -- 5 Conclusions -- References -- State-of-the-Art Analysis of Cuffless Methods for Blood Pressure Measurement -- 1 Introduction -- 2 Methods -- 3 Results -- 3.1 Contact-Based Alternatives -- 3.2 Contactless Alternatives -- 4 Discussion and Conclusion -- References -- Investigating the Suitable Materials for the Creation of Breast Lesions: A Simulation Study -- 1 Introduction -- 2 Software and Methods -- 2.1 Creation of Computational Model -- 2.2 Simulation Experiments -- 2.3 Evaluation of Models -- 3 Results -- 4 Conclusions -- References -- Sensitivity Analysis and Uncertainty Quantification of Effective Models for Microwave Thermal Ablation of Liver Tumors -- 1 Introduction -- 2 Model and Methods -- 2.1 Microwave Ablation Model -- 2.2 Model Parameters Included in Study -- 2.3 Sensitivity Analysis -- 2.4 Uncertainty Quantification -- 3 Numerical Results -- 3.1 Sensitivity Analysis -- 3.2 Uncertainty Quantification -- 4 Conclusions -- References -- A New System to Monitor Arteriovenous Fistula -- 1 Introduction -- 2 Materials and Methods -- 2.1 The Sensor -- 2.2 Signal Processing and Analysis.
3 Results -- 4 Conclusions -- References -- Minimal Forcemyography Human-Machine Interface for Hand Gesture Recognition -- 1 Introduction -- 2 Materials and Methods -- 2.1 FMG-Based HMI -- 2.2 Data Segmentation, Features Extraction and Hand Gesture Classification -- 3 Results -- 4 Conclusions and Discussion -- References -- On the Development of an Innovative Surgical Parallel Robotic System -- 1 Introduction -- 2 Materials and Methods -- 2.1 The Innovative Parallel Robotic System Used for SILS -- 2.2 Control System Architecture -- 2.3 The Hardware System Architecture of the PARA-SILSROB -- 2.4 PARA-SILSROB Master-Slave Architecture -- 3 Results -- 4 Conclusions -- References -- Ocular Torticollis Detection and Management Based on OpenPose -- 1 Introduction -- 2 Methods -- 3 Results -- References -- Development of a Portable Heart Rate Monitoring Device -- 1 Introduction -- 2 Materials and Methods -- 2.1 Components and Supplies -- 2.2 Design and Connections -- 2.3 Experimental Procedure -- 2.4 Data Transmission and Recording -- 3 Results -- 4 Conclusions -- References -- Is Innovation Crucial for the Artificial Respiration System Market? A Strategic Portfolio Assessment -- 1 Introduction -- 1.1 Methodology -- 2 Results -- 2.1 BCG Analysis of Solutions for Artificial Respiration -- 3 Conclusions -- References -- Methodology and Sensor Technology for Hydration Monitoring -- 1 Introduction -- 2 Theoretical Background -- 3 Methods for Physical Assessments -- 3.1 Bioelectrical Impedance Analysis (BIA) -- 3.2 Bioimpedance Spectroscopy (BIS) -- 3.3 Sonography -- 4 Biochemical Methods -- 4.1 Urine Analysis -- 4.2 Blood Analysis -- 4.3 Deuterium Dilution Method (DDM) -- 5 Multisensory Approaches -- 5.1 Data Fusion -- 5.2 Combination of Multisensory Approaches -- 6 Discussion -- 6.1 Biochemical Methods -- 6.2 Physical Assessments -- 6.3 Multisensory Methods.
7 Conclusions -- References -- Noninvasive System for Glucose Monitoring Based on the Galvanic Skin Response (GSR) -- 1 Introduction -- 2 Materials and Methods -- 2.1 The Electrical Model of the Skin -- 3 Results -- 3.1 Data Analysis -- 3.2 Correlation and Linear Regression -- 4 Conclusions -- References -- Factors Influencing Adoption of High-Value Innovation in Medical Technology Industry -- 1 Introduction -- 2 Literature Review -- 2.1 Research and Development -- 2.2 Business Management System -- 2.3 Entrepreneurship Orientation and Dynamics -- 2.4 Business Process Management -- 2.5 Product Portfolio Management -- 2.6 Service Delivery Management -- 2.7 Factors of High-Value Innovation -- 2.8 Definition of Medical Technology -- 2.9 Definition of High-Value Innovation -- 2.10 Research Objectives -- 2.11 Research Questions -- 2.12 Hypotheses -- 3 Research Methodology and Approach -- 4 Conceptual Framework -- 5 Data Analysis -- 6 Summary of Hypothesis Testing -- 7 Limitations and Scope for Future Research -- 8 Conclusions -- References -- Hardware Parameters for Trust Mechanisms in MIoT -- 1 Introduction -- 2 Related Work -- 3 Trust Calculation Methods -- 4 Parameter for Trust Calculation -- 5 Conclusions -- 6 Future Work -- References -- Pothole Detection Using Jetson Nano Embedded System - An Evaluation of Training Models -- 1 Introduction -- 2 Database and Methods -- 3 Results -- 4 Conclusions -- References -- Smart Healthcare System -- 1 Introduction -- 2 System Description -- 2.1 Description of the System -- 2.2 Toothbrush Description -- 2.3 Brushing Model -- 2.4 Pillbox Description -- 3 Results -- 4 Conclusions -- References -- A LabVIEW and P300 Speller Based Brain-Computer Interface for Controlling a Robotic Arm and a Mobile Robot by Using the GTEC Unicorn Headset -- 1 Introduction -- 2 Hardware System - Unicorn EEG and Robot System.
2.1 GTEC Unicorn Headset with 8 EEG Sensors.
Sommario/riassunto: This book gathers the proceedings of the 11th International Conference on E-Health and Bioengineering, EHB 2023, held in hybrid form on November 9–10, 2023, in/from Bucharest, Romania. This first volume of a three-volume set reports on advances in medical devices and instrumentation, for a wide range of applications including medical diagnosis and therapy, rehabilitation, and medical data management. It also describes the use of artificial intelligence in medicine for detecting and modeling diseases, health monitoring, medical decision making, and related applications. All in all, this book offers extensive and timely information to researchers and professionals in bioengineering, health informatics and related interdisciplinary fields.
Titolo autorizzato: Advances in Digital Health and Medical Bioengineering  Visualizza cluster
ISBN: 3-031-62502-1
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9910886101003321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui
Serie: IFMBE Proceedings, . 1433-9277 ; ; 109