Vai al contenuto principale della pagina

Feedwater line break analysis using RELAP5/MOD3.3 for steam generator blowdown load assessment / / prepared by Han-Sik Jung [and four others]



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Jung Han-Sik Visualizza persona
Titolo: Feedwater line break analysis using RELAP5/MOD3.3 for steam generator blowdown load assessment / / prepared by Han-Sik Jung [and four others] Visualizza cluster
Pubblicazione: Washington, DC : , : Division of Systems Analysis, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission, , November 2016
Descrizione fisica: 1 online resource (31 pages) : color illustrations
Soggetto topico: Nuclear power plants - Piping - Safety measures
Steam-boilers
Nuclear reactors - Cooling - Safety measures
Nuclear power plants - United States
Note generali: "Manuscript completed: February 2016; date published: November 2016."
"Doosan Heavy Industry and Construction."
"Korea Institute of Nuclear Safety."
"K. Tien, NRC project manager."
"Prepared as part of the Agreement of Research Participation and Technical Exchange under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)."
Nota di bibliografia: Includes bibliographical references (page 31).
Titolo autorizzato: Feedwater line break analysis using RELAP5  Visualizza cluster
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9910707802803321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui