Vai al contenuto principale della pagina

Renewable integrated power system stability and control / / Hêmin Golpîra, Arturo R. Messina, Hassan Bevrani



(Visualizza in formato marc)    (Visualizza in BIBFRAME)

Autore: Golpîra Hêmin Visualizza persona
Titolo: Renewable integrated power system stability and control / / Hêmin Golpîra, Arturo R. Messina, Hassan Bevrani Visualizza cluster
Pubblicazione: Hoboken, New Jersey : , : Wiley-IEEE Press, , [2021]
©2021
Descrizione fisica: 1 online resource (353 pages)
Disciplina: 621.31
Soggetto topico: Electric power systems
Persona (resp. second.): MessinaArturo R.
BevraniHassan
Nota di contenuto: Cover -- Title Page -- Copyright Page -- Contents -- Preface -- Acknowledgments -- Chapter 1 Introduction -- 1.1 Power System Stability and Control -- 1.2 Current State of Power System Stability and Control -- 1.2.1 Frequency Control -- 1.2.2 Voltage Control -- 1.2.3 Oscillation Damping -- 1.3 Data-Driven Wide-Area Power System Monitoring and Control -- 1.4 Dynamics Modeling and Parameters Estimation -- 1.4.1 Modeling of Frequency, Voltage, and Angle Controls -- 1.4.2 Parameters Estimation -- 1.5 Summary -- References -- Chapter 2 MG Penetrated Power Grid Modeling -- 2.1 Introduction -- 2.2 Basic Concepts -- 2.2.1 Dynamic Equivalencing -- 2.2.2 Background on Study Zone and External System -- 2.3 Power Grid Modeling -- 2.3.1 The Notion of Center-of Gravity (COG) -- 2.3.1.1 Key Concept -- 2.3.1.2 Basic Assumptions -- 2.3.1.3 Modeling Formulation -- 2.3.1.4 Local Frequency Estimation -- 2.3.1.5 Simulation Results -- 2.3.2 An Enhanced COG-Based Model -- 2.3.2.1 Key Concept -- 2.3.2.2 Simulation Results -- 2.3.3 Generalized Equivalent Model -- 2.3.3.1 Basic Logic -- 2.3.3.2 Simulation and Results -- 2.4 MG Equivalent Model -- 2.4.1 Islanded Mode -- 2.4.1.1 Synchronous-Based DG -- 2.4.1.2 Genset Model Validation -- 2.4.1.3 Inverter-Based DG -- 2.4.1.4 Inverter-Based DG Model Validation -- 2.4.2 Grid-Connected Mode -- 2.4.2.1 Basic Logic -- 2.4.2.2 Model Validation -- 2.5 Summary -- References -- Chapter 3 Stability Assessment of Power Grids with High Microgrid Penetration -- 3.1 Introduction -- 3.1.1 Motivation -- 3.1.2 Relations with Previous Literature -- 3.2 Frequency Stability Assessment -- 3.2.1 Background on Frequency Indices -- 3.2.1.1 Rate of Change of Frequency -- 3.2.1.2 Frequency Nadir -- 3.2.1.3 Delta Frequency Detection -- 3.2.2 Frequency Stability Assessment Under High MG Penetration Levels -- 3.2.3 Sensitivity Factors.
3.2.3.1 Frequency Response -- 3.2.3.2 Delta Frequency Detection -- 3.2.4 Simulation and Results -- 3.3 Maximum Penetration Level: Frequency Stability -- 3.3.1 Basic Principle -- 3.3.2 Background on MG Modeling -- 3.3.3 Minimum Inertia Related to Frequency Nadir -- 3.3.4 Minimum Inertia Related to Delta Frequency Detection -- 3.3.5 Minimum Inertia Related to RoCoF -- 3.3.6 Maximum Penetration Level -- 3.3.7 Simulation and Results -- 3.3.7.1 Analysis Tools -- 3.3.7.2 Dynamical Simulation Results -- 3.4 Small-Signal Stability Assessment -- 3.4.1 Basic Definition -- 3.4.2 Key Concept -- 3.4.3 Simulation and Results -- 3.5 Maximum Penetration Level: Small-Signal Stability -- 3.5.1 Basic Idea -- 3.5.2 Simulation and Results -- 3.6 Voltage-Based Realization of the MG-Integrated Power Grid -- 3.6.1 Key Concepts -- 3.6.2 Jacobian Sensitivities -- 3.6.2.1 V-P Sensitivity -- 3.6.2.2 V-Q Sensitivity -- 3.6.3 Simulation and Results -- 3.7 Summary -- References -- Chapter 4 Advanced Virtual Inertia Control and Optimal Placement -- 4.1 Introduction -- 4.2 Virtual Synchronous Generator -- 4.2.1 Concept and Structure -- 4.2.2 Basic Control Scheme and Applications -- 4.2.3 Application in Power System Dynamic Enhancement -- 4.2.3.1 Scenario 1: 10-MW Load Increase at Bus 9 -- 4.2.3.2 Scenario 2: 20-MW Power Command Decrease of G3 -- 4.2.4 Application to Power Grids with HVDC Systems -- 4.3 Dispatchable Inertia Placement -- 4.3.1 Frequency Dynamics Enhancement -- 4.3.1.1 Background: Literature Review -- 4.3.1.2 Virtual Inertia Modeling -- Main Idea -- MUSIC Analysis: Methodology and Application -- 4.3.1.3 Experimental Verification -- 4.3.1.4 Economic Modeling -- 4.3.1.5 Simulation and Results -- 4.3.1.6 Sensitivity Analysis -- 4.3.2 Small-Signal Stability -- 4.3.2.1 Objective Function -- 4.3.2.2 Simulation Results -- 4.4 Summary -- References.
Chapter 5 Wide-Area Voltage Monitoring in High-Renewable Integrated Power Systems -- 5.1 Introduction -- 5.2 Voltage Control Areas: A Background -- 5.2.1 Voltage Sensitivities -- 5.2.2 Electrical Distances -- 5.2.3 Reactive Control Zones and Pilot Nodes -- 5.2.3.1 Selection of Optimal Pilot Buses -- 5.2.3.2 Selection of Control Plants -- 5.2.4 Other Approaches -- 5.3 Data-driven Approaches -- 5.3.1 Wide-Area Voltage and Reactive Power Regulation -- 5.3.2 PMU-Based Voltage Monitoring -- 5.4 Theoretical Framework -- 5.4.1 Dynamic Trajectories -- 5.4.2 Spectral Graph Theory -- 5.4.3 Kernel Methods -- 5.4.3.1 Markov Matrices -- 5.4.3.2 The Markov Clustering Algorithm -- 5.4.4 Spatiotemporal Clustering -- 5.5 Case Study -- 5.5.1 Sensitivity Studies -- 5.5.2 Data-Driven Analysis -- 5.5.3 Measurement-Based Reactive Control Areas -- 5.5.3.1 Diffusion Maps -- 5.5.4 Direct Clustering -- 5.5.5 Correlation Analysis -- 5.5.5.1 Direct Analysis of Concatenated Data -- 5.5.5.2 Two-Way Correlation Analysis -- 5.5.5.3 Partial Least Squares Correlation -- 5.6 Summary -- References -- Chapter 6 Advanced Control Synthesis -- 6.1 Introduction -- 6.2 Frequency Dynamics Enhancement -- 6.2.1 Background: The Concept of Flexible Inertia -- 6.2.2 Frequency Dynamics Propagation -- 6.2.3 Inertia-Based Control Scheme -- 6.2.4 Flexible Inertia: Practical Considerations -- 6.2.5 Results and Discussions -- 6.3 Small Signal Stability Enhancement -- 6.3.1 Key Concept -- 6.3.2 Control Scheme Design -- 6.3.3 Simulation and Results -- 6.4 Summary -- References -- Chapter 7 Small-Signal and Transient Stability Assessment Using Data-Driven Approaches -- 7.1 Background and Motivation -- 7.2 Modal Characterization Using Data-Driven Approaches -- 7.2.1 Modal Decomposition -- 7.2.2 Multisignal Prony Analysis -- 7.2.2.1 Standard Prony Analysis -- 7.2.2.2 Modified Least-Squares Algorithm.
7.2.2.3 Multichannel Prony Analysis -- 7.2.2.4 Hankel-SVD Methods -- 7.2.3 Koopman and Dynamic Mode Decomposition Representations -- 7.2.3.1 The Koopman Operator -- 7.2.4 Dynamic Mode Decomposition -- 7.2.4.1 SVD-Based Methods -- 7.2.4.2 The Companion Matrix Approach -- 7.2.4.3 Energy Criteria -- 7.3 Studies of a Small-Scale Power System Model -- 7.3.1 System Data and Operating Scenarios -- 7.3.2 Exploratory Small-Signal Analysis -- 7.3.3 Large System Performance -- 7.3.3.1 Cases B-C -- 7.3.3.2 Case D -- 7.3.4 Mode Shape Identification -- 7.3.5 Temporal Clustering -- 7.4 Large-Scale System Study -- 7.4.1 Case Study Description -- 7.4.2 Renewable Generator Modeling -- 7.4.3 Effect of Inverter-Based DGs on Oscillatory Stability -- 7.4.4 Large System Performance -- 7.4.5 Model Validation -- 7.4.5.1 Reconstructed Flow Fields -- 7.4.6 Identification of Mode Shapes Using DMD -- 7.5 Analysis Results and Discussion -- References -- Chapter 8 Solar and Wind Integration Case Studies -- 8.1 General Context and Motivation -- 8.2 Study System -- 8.3 Wind Power Integration in the South Systems -- 8.3.1 Study Region -- 8.3.2 Existing System Limitations -- 8.4 Impact of Increased Wind Penetration on the System Performance -- 8.4.1 Study Considerations and Scenario Development -- 8.4.2 Base Case Assessment -- 8.4.2.1 System Oscillatory Response -- 8.4.3 High Wind Penetration Case -- 8.5 Frequency Response -- 8.5.1 Frequency Variations -- 8.5.2 Wind and Hydropower Coordination -- 8.5.3 Response to Loss-of-Generation Events -- 8.6 Effect of Voltage Control on System Dynamic Performance -- 8.6.1 Voltage Support and Reactive Power Dispatch -- 8.6.2 Effect of Voltage Control Characteristics -- 8.7 Summary -- References -- Index.
Sommario/riassunto: "Increased needs for electrical energy as well as environmental concerns besides growing attempts to reduce dependency on fossil fuel resources have caused power system industries all around the world to set an ambitious target of renewable generation. Therefore, the capacity of installed inverter-based distributed generators (DGs) and renewable energy sources (RESs), individually or through the microgrids (MGs), in power systems is rapidly growing; and this increses the significance of renewable integrated power system stability and control as a challenging issue."--
Titolo autorizzato: Renewable integrated power system stability and control  Visualizza cluster
ISBN: 1-119-68977-5
1-119-68983-X
1-119-68982-1
Formato: Materiale a stampa
Livello bibliografico Monografia
Lingua di pubblicazione: Inglese
Record Nr.: 9910830586803321
Lo trovi qui: Univ. Federico II
Opac: Controlla la disponibilità qui
Serie: Wiley - IEEE