LEADER 01862nam 2200325 n 450 001 996574816003316 005 20231215145104.0 010 $a1-5044-8000-7 035 $a(CKB)5600000000432758 035 $a(NjHacI)995600000000432758 035 $a(EXLCZ)995600000000432758 100 $a20231215d2022 uy 0 101 0 $aeng 135 $aur||||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 10$a184_1017.2-2021 - IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation /$fInstitute of Electrical and Electronics Engineers 210 1$aNew York, USA :$cIEEE,$d2022. 215 $a1 online resource (44 pages) 330 $aMinimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or metallic barrier, and armor or encapsulating material. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or metallic barrier cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document. 606 $aElectric cables$vCongresses 615 0$aElectric cables 676 $a621.31934 801 0$bNjHacI 801 1$bNjHacl 906 $aDOCUMENT 912 $a996574816003316 996 $a184_1017.2-2021 - IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation$93652164 997 $aUNISA