LEADER 02030oam 2200589 450 001 9910712012303321 005 20190412145502.0 035 $a(CKB)5470000002489983 035 $a(OCoLC)961333376 035 $a(EXLCZ)995470000002489983 100 $a20161028d1961 ua 0 101 0 $aeng 135 $aur||||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 10$aSurface water supply of the United States, 1959$hPart 1-B$iNorth Atlantic slope basins, New York to York River /$fprepared under the direction of J.V.B. Wells 210 1$a[Washington, D.C.] :$cUnited States Department of the Interior, Geological Survey,$d1961. 210 2$aWashington :$cUnited States Government Printing Office. 215 $a1 online resource (xi, 537 pages) $cillustrations, maps 225 1 $aGeological Survey water-supply paper ;$v1622 300 $a"Prepared in cooperation with the States of Delaware, Maryland, Massachusetts, New Jersey, New York, Pennsylvania, Vermont, Virginia, and West Virginia, and with other agencies." 300 $aIncludes index. 606 $aWater quality$zNortheastern States 606 $aWater-supply$zNortheastern States 606 $aWater quality$2fast 606 $aWater-supply$2fast 607 $aNortheastern States$2fast 615 0$aWater quality 615 0$aWater-supply 615 7$aWater quality. 615 7$aWater-supply. 700 $aWells$b J. V. B.$01385991 712 02$aGeological Survey (U.S.), 712 02$aDelaware. 712 02$aMaryland. 712 02$aMassachusetts. 712 02$aNew Jersey. 712 02$aNew York (State) 712 02$aPennsylvania. 712 02$aVermont. 712 02$aVirginia. 712 02$aWest Virginia. 801 0$bCOP 801 1$bCOP 801 2$bOCLCO 801 2$bOCLCF 801 2$bGPO 906 $aBOOK 912 $a9910712012303321 996 $aSurface water supply of the United States, 1959$93450070 997 $aUNINA LEADER 02116nam 2200349 450 001 996280197003316 005 20231206165720.0 010 $a1-5044-2276-7 035 $a(CKB)3710000001362123 035 $a(NjHacI)993710000001362123 035 $a(EXLCZ)993710000001362123 100 $a20231206d2017 uy 0 101 0 $aeng 135 $aur||||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 10$aIEEE Std C37.13.1-2016 (Revision of IEEE Std C37.13.1-2006) $eIEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage (600 V AC and Below) Power Circuit Breaker Switchgear /$fIEEE 210 1$aNew York :$cIEEE,$d2017. 215 $a1 online resource 330 $aDefinite-purpose switching devices for use in metal-enclosed low-voltage power circuit breaker switchgear are covered in this standard. The switching devices are fused, drawout type, three-pole construction, with one or more rated maximum ac voltages of 600 V, 508 V, and 254 V for application on systems having nominal ac voltages of 600 V, 480 V, and 240 V. The switching devices are power operated with integral or separately mounted overcurrent protective devices. Service conditions, ratings, functional components, temperature limitations and classifications of insulating materials, insulation (dielectric) withstand voltage requirements, test procedures, and application are addressed in this standard. The switching devices are normally used in applications that require frequency of operation greater than normal operations expected of low-voltage power circuit breakers. 517 $aC37.13.1-2016 - IEEE Standard for Definite-Purpose Switching Devices for Use in Metal-Enclosed Low-Voltage 517 $aIEEE Std C37.13.1-2016 606 $aElectric circuit-breakers 615 0$aElectric circuit-breakers. 676 $a621.317 801 0$bNjHacI 801 1$bNjHacl 906 $aDOCUMENT 912 $a996280197003316 996 $aIEEE Std C37.13.1-2016 (Revision of IEEE Std C37.13.1-2006)$93647514 997 $aUNISA