LEADER 05333nam 22006731 450 001 9910790523403321 005 20230803021958.0 010 $a1-61499-266-5 035 $a(CKB)2550000001130218 035 $a(EBL)1477318 035 $a(SSID)ssj0000967838 035 $a(PQKBManifestationID)12467899 035 $a(PQKBTitleCode)TC0000967838 035 $a(PQKBWorkID)10978193 035 $a(PQKB)10505164 035 $a(Au-PeEL)EBL1477318 035 $a(CaPaEBR)ebr10785482 035 $a(CaONFJC)MIL530314 035 $a(MiAaPQ)EBC1477318 035 $a(OCoLC)860846061 035 $a(EXLCZ)992550000001130218 100 $a20130717h20132013 uy 0 101 0 $aeng 135 $aur|n|---||||| 181 $ctxt 182 $cc 183 $acr 200 10$aHealth informatics $edigital health service delivery, the future is now! : selected papers from the 21st Australian National Health Informatics Conference (HIC 2013) /$fedited by Heather Grain and Louise K. Schaper 210 1$aAmsterdam ;$aWashington, D. C. :$cIOS Press,$d[2013] 210 4$d©2013 215 $a1 online resource (196 p.) 225 1 $aStudies in health technology and informatics,$x0926-9630 ;$vvolume 188 300 $aDescription based upon print version of record. 311 $a1-61499-265-7 311 $a1-299-99063-0 320 $aIncludes bibliographical references and index. 327 $a""Title Page""; ""Preface""; ""Acknowledgements""; ""Contents""; ""Australia's Personally Controlled Electronic Health Record and Primary Healthcare: Generating a Framework for Implementation and Evaluation""; ""Computerisation of Perinatal Data Entry: Is the Data Accurate?""; ""Improving the Cancer Patient Journey""; ""Integrating a Mobile Health Setup in a Chronic Disease Management Network""; ""E-Health in Australia and Elsewhere: A Comparison and Lessons for the Near Future""; ""Monitoring the Impact of the Electronic Medical Record on the Quality of Laboratory Test Ordering Practices"" 327 $a""A Technological Evaluation of the Microsoft Kinect for Automated Behavioural Mapping at Bed Rest""""Propensity of People with Long-Term Conditions to Use Personal Health Records""; ""Automated Validation of Patient Safety Clinical Incident Classification: Macro Analysis""; ""Designing a Diabetes Mobile Application with Social Network Support""; ""Hospital Level Analysis to Improve Patient Flow""; ""E-Health as a Life Long Learning Process: How to Prepare Health Professionals for This Journey"" 327 $a""The Effect of Electronic Pathology Ordering in Emergency Departments on One Aspect of Test Turn Around Time: A Failure Time Analysis""""Building an Educated Health Informatics Workforce - The New Zealand Experience""; ""Using NLP to Identify Cancer Cases in Imaging Reports Drawn from Radiology Information Systems""; ""Clinical Information Access Portal (CIAP) Use by NSW Health Staff over 15 Years""; ""A Spatial Informatics for Aged Care""; ""An Approach to Designing Viable and Sustainable Telehealth Services"" 327 $a""Examination of Changes in Pathology Tests Ordered by Diagnosis-Related Group (DRGs) Following CPOE Introduction""""Care Provision Expectations of Remote Adult Children of Ageing Parents""; ""Iterative Refinement of SemLink to Enhance Patient Readability of Discharge Summaries""; ""Using Personal Health Information: Do We Manage Conflicting Interests?""; ""Evaluation of a Medicines List iPhone App""; ""Creating Context: Making Sense of Geo-Location and Social Media Data for Health""; ""It Will Never Happen to Us: The Likelihood and Impact of Privacy Breaches on Health Data in Australia"" 327 $a""An Evaluation of Clinician's View on Electronic Pathology Reporting Sign Off and Patient Safety""""Understanding How Clinical Judgement and Communicative Practices Interact with the Use of an Electronic Clinical Handover System""; ""Hierarchical Classifier Approach to Physical Activity Recognition via Wearable Smartphone Tri-Axial Accelerometer""; ""Subject Index""; ""Author Index"" 330 $aHealthcare systems around the world are going through immense changes as innovative approaches to healthcare delivery are adopted to reduce cost and improve quality of care. Health informatics professionals are increasingly required to support these changes, and innovation, learning from experience and sharing ideas are essential to delivering the promises of e-health.This book presents the proceedings of the 21st Australian National Health Informatics Conference (HIC 2013), held in Adelaide, Australia in July 2013. The theme of HIC 2013 is 'Digital Health Service Delivery - the Future is Now! 410 0$aStudies in health technology and informatics ;$vv. 188. 517 3 $aHIC 2013 606 $aMedical informatics$vCongresses 606 $aMedicine$xData processing$vCongresses 615 0$aMedical informatics 615 0$aMedicine$xData processing 676 $a610.285 701 $aGrain$b Heather$01514267 701 $aSchaper$b Louise K$01482547 712 12$aAustralian National Health Informatics Conference 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9910790523403321 996 $aHealth informatics$93749242 997 $aUNINA LEADER 05380nam 2200673 a 450 001 9911020005203321 005 20251116153534.0 010 $a1-282-00792-0 010 $a9786612007927 010 $a3-433-60005-8 010 $a3-433-60006-6 035 $a(CKB)1000000000550451 035 $a(EBL)482045 035 $a(OCoLC)309932476 035 $a(SSID)ssj0000715320 035 $a(PQKBManifestationID)11956087 035 $a(PQKBTitleCode)TC0000715320 035 $a(PQKBWorkID)10701208 035 $a(PQKB)10608924 035 $a(MiAaPQ)EBC482045 035 $a(EXLCZ)991000000000550451 100 $a20120201d2008 uy 0 101 0 $ager 135 $aur|n|---||||| 181 $ctxt 182 $cc 183 $acr 200 10$aBauphysik $eKlima, Warme, Feuchte, Schall : Grundlagen, Anwendungen, Beispiele /$fPeter Haupl 210 $aBerlin $cErnst & Sohn$d2008 215 $a1 online resource (566 p.) 300 $aDescription based upon print version of record. 311 08$a3-433-01842-1 320 $aIncludes bibliographical references. 327 $aBauphysik Klima Wa?rme Feuchte Schall Grundlagen, Anwendungen, Beispiele; Vorwort; Inhaltsverzeichnis; Einfu?hrung; KLIMA; 1 Außen- und Raumklima; 1.1 Außenklima; 1.1.1 Außenlufttemperatur; 1.1.1.1 Jahresgang der Außenlufttemperatur; 1.1.1.2 Simulation des tatsa?chlichen Temperaturganges; 1.1.1.3 Tagesgang der Außenlufttemperatur; 1.1.1.4 Summenha?ufigkeit der Außenlufttemperatur; 1.1.2. Wa?rmestrahlungsbelastung; 1.1.2.1 Kurzwellige Strahlungswa?rmestromdichte auf eine Horizontalfla?che; 1.1.2.2 Strahlungswa?rmestromdichte auf beliebig orientierte und geneigte Fla?chen 327 $a1.1.2.3 Langwellige Abstrahlung1.1.3 Wasserdampfdruck und relative Luftfeuchtigkeit; 1.1.3.1 Wasserdampfsa?ttigungsdruck; 1.1.3.2 Tatsa?chlicher Wasserdampfdruck; 1.1.3.3 Relative Luftfeuchtigkeit; 1.1.4 Niederschlag und Wind; 1.1.4.1 Regenstromdichte; 1.1.4.2 Windgeschwindigkeit und Windrichtung; 1.1.4.3 Windniederschlagsgebiete; 1.1.5 Schlagregenstromdichte auf eine vertikale Geba?udefla?che; 1.1.6 Testreferenzjahr; 1.1.7 Lokalklimate; 1.2 Raumklima; 1.2.1 Raumtemperaturen; 1.2.1.1 Energieumsatz des Menschen; 1.2.1.2 Raumlufttemperatur, Umschließungsfla?chen- und Empfindungstemperatur 327 $a1.2.2 Raumluftfeuchte1.2.2.1 Relative Luftfeuchtigkeit - Raumklimaklassen; 1.2.2.2 Enthalpie und Wasserdampfgehalt (h-x-Diagramm); 1.2.2.3 Taupunkttemperatur; 1.2.2.4 Einfluss der Luftfeuchte und Stro?mungsgeschwindigkeit auf die Behaglichkeit; WA?RME; 2 Grundlagen des Wa?rmetransportes; 2.1 Wa?rmeleitung; 2.1.1 Wa?rmeleitungsgleichung; 2.1.2 Stationa?re Lo?sung der Wa?rmeleitungsgleichung; 2.2 Wa?rmekonvektion; 2.2.1 Transportgleichungssystem fu?r kombinierte Wa?rmeleitung und Wa?rmestro?mung; 2.2.2 Konvektiver Wa?rmeu?bergang an einer Bauteiloberfla?che 327 $a2.2.3 A?hnlichkeit von Stro?mungs - und Temperaturfeldern2.3 Wa?rmestrahlung; 2.3.1 Strahlungsgesetze; 2.3.2 Strahlungswa?rmeaustausch zwischen Bauteilfla?chen; 2.3.2.1 Wa?rmestrahlung zwischen zwei planparallelen Fla?chen; 2.3.2.2 Wa?rmestrahlung zwischen zwei beliebigen sich umschließenden Fla?chen; 2.3.2.3 Einstrahlzahlen; 2.4 Gesamtwa?rmeu?bergang an einer Bauteiloberfla?che; 3 Thermisches Verhalten von Bauwerksteilen; 3.1 Stationa?rer Wa?rmedurchgang bei mehrschichtigen Bauwerksteilen 327 $a3.1.1 Ermittlung des vorhandenen Wa?rmewiderstands R, des Wa?rmedurchgangswertes U und des stationa?ren Temperaturprofils im Winter3.1.2 Mindestanforderungen an den R-Wert bzw. an den U-Wert; 3.1.2.1 Kriterium 1 : Tauwasserfreiheit an der Bauteiloberfla?che; 3.1.2.2 Kriterium 2 : Vermeidung von Schimmel an Bauteiloberfla?chen; 3.1.2.3 Kriterium 3 : Vermeidung einer Abku?hlung der Bauteiloberfla?che unter 17°C; 3.1.3 Wa?rmedurchgang parallel liegender Bauteile; 3.1.4 Wa?rmedurchgang bei Fenstern; 3.1.5 Belu?fttete Umfassungskonstruktionen; 3.1.5.1 Belu?ftete Außenwand; 3.1.5.2 Belu?ftetes Steildach 327 $a3.1.5.3 Vergleich der Spalttemperatur und der Stro?mungsgeschwindigkeit mit Messergebnissen 330 $aKlimaschutzgerecht und energieoptimiert Bauen heißt: volle Gewa?hrleistung der Funktions- und Eigensicherung von Geba?uden, wie Einhaltung eines nutzerada?quaten Raumklimas und Vermeidung von Feuchtescha?den an Bauteilen, bei gegebenem Außenklima unter intelligentem Einsatz von bauphysikalischen, baustofflichen, baukonstruktiven, anlagentechnischen und gestalterischen Mitteln.Das vorliegende Buch konzentriert sich auf das bauphysikalische Instrumentarium. Es ist klassisch gegliedert in die Teile Klima, Wa?rme, Feuchte, Schall weicht aber in den Einzelinhalten und Vermittlungsmethoden von eingef 606 $aBuildings$xEnvironmental engineering 606 $aHeating 606 $aVentilation 606 $aDampness in buildings 606 $aSoundproofing 615 0$aBuildings$xEnvironmental engineering. 615 0$aHeating. 615 0$aVentilation. 615 0$aDampness in buildings. 615 0$aSoundproofing. 676 $a693.8 700 $aHa?upl$b Peter$01345640 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9911020005203321 996 $aBauphysik$93071366 997 $aUNINA