LEADER 05211nam 22006614a 450 001 9910841340403321 005 20230829004834.0 010 $a0-470-61222-3 010 $a1-280-60345-3 010 $a9786610603459 010 $a1-84704-456-5 010 $a0-470-39445-5 010 $a1-84704-556-1 035 $a(CKB)1000000000335565 035 $a(EBL)700724 035 $a(OCoLC)769341517 035 $a(SSID)ssj0000229544 035 $a(PQKBManifestationID)11198491 035 $a(PQKBTitleCode)TC0000229544 035 $a(PQKBWorkID)10172183 035 $a(PQKB)10167876 035 $a(MiAaPQ)EBC700724 035 $a(MiAaPQ)EBC261976 035 $a(Au-PeEL)EBL261976 035 $a(OCoLC)156937664 035 $a(EXLCZ)991000000000335565 100 $a20060313d2006 uy 0 101 0 $aeng 135 $aur|n|---||||| 181 $ctxt 182 $cc 183 $acr 200 10$aProtection of electrical networks$b[electronic resource] /$fChristophe Pre?ve? 210 $aLondon ;$aNewport Beach, CA $cISTE$dc2006 215 $a1 online resource (510 p.) 225 1 $aISTE ;$vv.94 300 $aIncludes index. 311 $a1-905209-06-1 327 $aProtection of Electrical Networks; Table of Contents; Chapter 1. Network Structures; 1.1. General structure of the private distribution network; 1.2. The supply source; 1.3. HV consumer substations; 1.4. MV power supply; 1.4.1. Different MV service connections; 1.4.2. MV consumer substations; 1.5. MV networks inside the site; 1.5.1. MV switchboard power supply modes; 1.5.2. MV network structures; 1.6. LV networks inside the site; 1.6.1. LV switchboard supply modes; 1.6.2. LV switchboards backed up by generators; 1.6.3. LV switchboards backed up by an uninterruptible power supply (UPS) 327 $a1.7. Industrial networks with internal generation1.8. Examples of standard networks; Chapter 2. Earthing Systems; 2.1. Earthing systems at low voltage; 2.1.1. Different earthing systems - definition and arrangements; 2.1.2. Comparison of different earthing systems in low voltage; 2.1.2.1. Unearthed or impedance-earthed neutral (IT system); 2.1.2.2. Directly earthed neutral (TT system); 2.1.2.3. Connecting the exposed conductive parts to the neutral (TNC - TNS systems); 2.2. Medium voltage earthing systems; 2.2.1. Different earthing systems - definition and arrangements 327 $a2.2.2. Comparison of different medium voltage earthing systems2.2.2.1. Direct earthing; 2.2.2.2. Unearthed; 2.2.2.3. Limiting resistance earthing; 2.2.2.4. Limiting reactance earthing; 2.2.2.5. Peterson coil earthing; 2.3. Creating neutral earthing; 2.3.1. MV installation resistance earthing; 2.3.2. Reactance or Petersen coil earthing of an MV installation; 2.3.3. Direct earthing of an MV or LV installation; 2.4. Specific installation characteristics in LV unearthed systems; 2.4.1. Installing a permanent insulation monitor; 2.4.2. Installing an overvoltage limiter 327 $a2.4.3. Location of earth faults by a low frequency generator (2-10 Hz)2.5. Specific installation characteristics of an MV unearthed system; 2.5.1. Insulation monitoring; 2.5.2. Location of the first insulation fault; Chapter 3. Main Faults Occurring in Networks and Machines; 3.1. Short-circuits; 3.1.1. Short-circuit characteristics; 3.1.2. Different types of short-circuits; 3.1.3. Causes of short-circuits; 3.2. Other types of faults; Chapter 4. Short-circuits; 4.1. Establishment of short-circuit currents and wave form 327 $a4.1.1. Establishment of the short-circuit at the utility's supply terminals4.1.2. Establishment of the short-circuit current at the terminals of a generator; 4.2. Short-circuit current calculating method; 4.2.1. Symmetrical three-phase short-circuit; 4.2.1.1. Equivalent impedance of an element across a transformer; 4.2.1.2. Impedance of parallel links; 4.2.1.3. Expression of impedances as a percentage and short-circuit voltage as a percentage; 4.2.1.4. Impedance values of different network elements; 4.2.1.5. Contribution of motors to the short-circuit current value 327 $a4.2.1.6. Example of a symmetrical three-phase short-circuit calculation 330 $aThis book, designed for engineers, technicians, designers and operators working with electrical networks, contains theoretical and practical information on the design and set-up of protection systems.Protection of Electrical Networks first discusses network structures and grounding systems together with problems that can occur in networks. It goes on to cover current and voltage transformers, protection functions, circuit breakers and fuses.Practical explanations of how protection systems function are given, and these, together with tables of settings, make this book suitable for any r 410 0$aISTE 606 $aElectric networks$xProtection 615 0$aElectric networks$xProtection. 676 $a621.319/2 676 $a621.3192 700 $aPreve$b Christophe$f1964-$0985539 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9910841340403321 996 $aProtection of electrical networks$92252748 997 $aUNINA