LEADER 03015nam 2200553 450 001 9910827766703321 005 20230801232602.0 010 $a1-78040-047-0 035 $a(CKB)3440000000000634 035 $a(EBL)3121249 035 $a(OCoLC)922995976 035 $a(SSID)ssj0001502260 035 $a(PQKBManifestationID)11814914 035 $a(PQKBTitleCode)TC0001502260 035 $a(PQKBWorkID)11455195 035 $a(PQKB)10655386 035 $a(MiAaPQ)EBC3121249 035 $a(Au-PeEL)EBL3121249 035 $a(CaPaEBR)ebr10994528 035 $a(EXLCZ)993440000000000634 100 $a20141220h20122012 uy 0 101 0 $aeng 135 $aur|n|---||||| 181 $ctxt 182 $cc 183 $acr 200 10$aAutomatic vacuum flushing technology for combined sewer solids $elaboratory testing and proposed improvements /$fby Dr. Qizhong Guo 210 1$aLondon, England :$cIWA Publishing,$d2012. 210 4$dİ2012 215 $a1 online resource (61 p.) 225 1 $aWERF Research Report Series 300 $aDescription based upon print version of record. 320 $aIncludes bibliographical references. 327 $aCover; Copyright; Acknowledgments; Abstract and Benefits; Table of Contents; List of Tables; List of Figures; List of Acronyms; Executive Summary; Chapter 1.0: Project Background and Objective; 1.1 Project Background; 1.2 Objective; Chapter 2.0: Approach; 2.1 Original Work Plan; 2.2 Revised Work Plan; 2.3 Task 1 - Review of Sewer Sediment Flushing Technologies; 2.3.1 Sewer Flushing Technologies; 2.3.2 Overview of Field Demonstration of Sewer Flushing Technologies; 2.4 Task 2 - Laboratory Quantification of Automatic Vacuum Flushing System; 2.4.1 Experimental Design, Equipment, and Procedures 327 $a2.4.2 Experimental Results and Discussion2.5 Task 3 - Testing of Modified Vacuum Flushing Designs; 2.5.1 Float and Seal Device; 2.5.2 Sealing Lever Device; 2.6 Task 4 - Evaluation of Field Demonstration Site; 2.7 Task 5 - Performance Evaluation of Installed Flushing Systems; 2.7.1 Paerdegat Basin CSO Facility - Brooklyn NY; 2.7.2 Drain Flushing Vault 1 - Freshpond Parkway, Cambridge MA; 2.7.3 Alley Creek CSO Facility - Queens NY; 2.7.4 Muddy Creek Basin (CSO 198) - Cincinnati OH; 2.7.5 Wheeler Avenue CSO Flood Control Basin - Louisville KY; 2.7.6 Water Pollution Control Facility - Auburn IN 327 $a2.7.7 Typical Problems in Systems Visited2.7.8 Advantages and Disadvantages of Observed and Proposed Systems; Chapter 3.0: Conclusions; Appendix A; References 410 0$aWERF Research Report Series 606 $aVacuum technology 615 0$aVacuum technology. 676 $a621.55 700 $aGuo$b Qizhong$01716705 712 02$aWater Environment Research Foundation. 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9910827766703321 996 $aAutomatic vacuum flushing technology for combined sewer solids$94112204 997 $aUNINA