LEADER 01852oam 2200493 450 001 9910715204703321 005 20210309143515.0 035 $a(CKB)5470000002509982 035 $a(OCoLC)1236126698 035 $a(EXLCZ)995470000002509982 100 $a20210204d1989 ua 0 101 0 $aeng 135 $aurbn||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 00$aExcessive temperatures in emergency core cooling system piping located outside containment 210 1$aWashington, D.C. :$cUnited States Nuclear Regulatory Commission, Office of Nuclear Reactor Regulation,$d1989. 215 $a1 online resource 225 1 $aInformation notice ;$vno. 89-36 300 $a"April 4, 1989." 606 $aNuclear power plants$xPiping$zUnited States 606 $aEmergency core cooling systems$zUnited States 606 $aNuclear reactors$xMaterials$xThermal properties$zUnited States 606 $aEmergency core cooling systems$2fast 606 $aNuclear power plants$xPiping$2fast 606 $aNuclear reactors$xMaterials$xThermal properties$2fast 607 $aUnited States$2fast 615 0$aNuclear power plants$xPiping 615 0$aEmergency core cooling systems 615 0$aNuclear reactors$xMaterials$xThermal properties 615 7$aEmergency core cooling systems. 615 7$aNuclear power plants$xPiping. 615 7$aNuclear reactors$xMaterials$xThermal properties. 712 02$aU.S. Nuclear Regulatory Commission.$bOffice of Nuclear Reactor Regulation, 801 0$bGPO 801 1$bGPO 801 2$bOCLCO 801 2$bOCLCF 801 2$bGPO 906 $aBOOK 912 $a9910715204703321 996 $aExcessive temperatures in emergency core cooling system piping located outside containment$93278751 997 $aUNINA