LEADER 02074nam 2200445I 450 001 9910707643303321 005 20161004135747.0 035 $a(CKB)5470000002466106 035 $a(OCoLC)959837943 035 $a(EXLCZ)995470000002466106 100 $a20161004j201609 ua 0 101 0 $aeng 135 $aur||||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 10$aValidation of RELAP5 model of ringhals 4 against a load step test at uprated power /$fprepared by J. Ba?na?ti and A. Stathis 210 1$aWashington, DC :$cDivision of Systems Analysis, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission,$dSeptember 2016. 215 $a1 online resource (various pagings) $cillustrations 225 1 $aInternational agreement report ;$v0468 300 $a"Chalmers University of Technology, Department of Applied Physics, Division of Nuclear Engineering." 300 $a"K. Tien, NRC project manager." 300 $a"Manuscript completed: December 2015; date published: September 2016." 300 $a"Prepared as part of the Agreement on Research Participation and Technical Exchange under the Thermal-Hydraulic Code Applications and Maintenance Program (CAMP)." 300 $a"Technical"--Bibliographic data sheet. 320 $aIncludes bibliographical references. 517 3 $aValidation of RELAP5 model of ringhals four against a load step test at uprated power 606 $aPressurized water reactors$xControl$xAnalysis 606 $aNuclear power plants$xSafety measures 615 0$aPressurized water reactors$xControl$xAnalysis. 615 0$aNuclear power plants$xSafety measures. 700 $aBa?na?ti$b J$g(Jozsef),$01409053 702 $aStathis$b A. 712 02$aU.S. Nuclear Regulatory Commission.$bDivision of Systems Analysis, 801 0$bGPO 801 1$bGPO 906 $aBOOK 912 $a9910707643303321 996 $aValidation of RELAP5 model of ringhals 4 against a load step test at uprated power$93535290 997 $aUNINA