LEADER 01850oam 2200481Ia 450 001 9910692060203321 005 20160128100521.0 035 $a(CKB)5470000002350821 035 9 $aocm52907002 035 $a(OCoLC)52907002 035 $a(EXLCZ)995470000002350821 100 $a20030825d2003 ua 0 101 0 $aeng 135 $aurbn||||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 00$aAdvanced nondestructive evaluation for steam generator tubing$b[electronic resource] /$fprepared by Division of Engineering Technology, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission 205 $aCorr. ed. 210 1$aWashington, DC :$cU.S. Nuclear Regulatory Commission,$d[2003] 215 $axvii, 94 pages $cdigital, PDF file 300 $aTitle from title screen (viewed June 3, 2003). 300 $a"Errata, April 30, 2003." 300 $a"This publication supersedes and replaces NUREG/CR-6746 due to corrected equations." 300 $a"Date Published: September 2001." 300 $a"Report Number: NUREG/CR-6746." 300 $a"ANL-01/21." 320 $a"Includes bibliographical references. 606 $aTubes$xEvaluation 606 $aNondestructive testing 606 $aSteam power plants$xEquipment and supplies$xEvaluation 615 0$aTubes$xEvaluation. 615 0$aNondestructive testing. 615 0$aSteam power plants$xEquipment and supplies$xEvaluation. 712 02$aU.S. Nuclear Regulatory Commission.$bOffice of Nuclear Regulatory Research.$bDivision of Engineering Technology. 801 0$bGPO 801 1$bGPO 801 2$bOCLCQ 801 2$bGPO 906 $aBOOK 912 $a9910692060203321 996 $aAdvanced nondestructive evaluation for steam generator tubing$93194386 997 $aUNINA