LEADER 04969oam 2200493 450 001 9910491028603321 005 20231213210657.0 010 $a981-16-2715-0 035 $a(CKB)4100000011978145 035 $a(MiAaPQ)EBC6676313 035 $a(Au-PeEL)EBL6676313 035 $a(OCoLC)1260345107 035 $a(EXLCZ)994100000011978145 100 $a20220329d2021 uy 0 101 0 $aeng 135 $aurcnu|||||||| 181 $ctxt$2rdacontent 182 $cc$2rdamedia 183 $acr$2rdacarrier 200 10$aConcrete-filled double skin steel tubular column with hybrid fibre reinforced polymer $epost fire repair /$fKok Keong Choong [and five others] 210 1$aGateway East, Singapore :$cSpringer,$d[2021] 210 4$d©2021 215 $a1 online resource (xv, 81 pages) $cillustrations (some color) 225 1 $aSpringerBriefs in applied sciences and technology 311 0 $a981-16-2714-2 327 $aIntro -- Foreword -- Preface -- Acknowledgements -- Contents -- Abbreviations -- Symbols -- 1 Introduction -- References -- 2 Literature Review -- 2.1 Concrete-Filled Double Skin Steel Tubular (CFDST) Columns -- 2.2 Background on Fire Test of Structural Elements -- 2.2.1 Fire Test -- 2.2.2 Fire Test in Standards and Codes -- 2.2.3 Fire Test in Previous Research Studies -- 2.2.4 Fire Provision of Concrete-Filled Double Skin Steel Tubular (CFDST) Columns in Standards/Codes -- 2.2.5 Fire Provision in Malaysia -- 2.3 Behavior of Concrete-Filled Double Skin Steel Tubular Columns Exposed to Fire -- References -- 3 Post-fire Behavior of Concrete-Filled Double Skin Steel Tubular Columns -- 3.1 Concrete -- 3.2 Steel -- 3.3 Concrete-Filled Steel Tubular (CFST) Columns and Concrete-Filled Double Skin Steel Tubular (CFDST) Columns -- 3.3.1 Residual Strength, Stiffness and Ductility of Fire-Damaged CFST Columns -- 3.3.2 Cross-Sectional Dimension -- 3.3.3 Exposure Time -- 3.3.4 Temperature Distribution of Concrete-Filled Double Skin Steel Tubular (CFDST) Columns -- 3.4 Repair of Fire-Damaged Concrete-Filled Steel Tubular (CFST) Columns Using Fiber Reinforced Polymer (FRP) -- References -- 4 Temperature Distribution and Post-fire Behavior of Concrete-Filled Double Skin Steel Tubular Columns -- 4.1 Physical Appearance After Fire Exposure -- 4.2 Effect of Different Diameter and Fire Exposure Time Towards Concrete and Inner Steel Tube Temperature -- 4.2.1 Time-Temperature Curve of Concrete-Filled Double Skin Steel Tubular (CFDST) Columns -- 4.3 Effect of Thickness on Residual Strength Index, Secant Stiffness and Ductility Index -- 4.4 Effect of Fire Exposure Time on Residual Strength Index, Secant Stiffness and Ductility Index -- References -- 5 Repair of Fire-Damaged Concrete-Filled Double Skin Steel Tubular Columns with Fiber Reinforced Polymer (FRP). 327 $a5.1 Failure Pattern of Repaired Fire-Damaged Concrete-Filled Double Skin Steel Tubular (CFDST) Column -- 5.2 Repaired of Fire-Damaged Concrete-Filled Double Skin Steel Tubular (CFDST) Columns with Single Layer of Fiber Reinforced Polymer (FRP) -- 5.2.1 Effect of Fiber Reinforced Polymer (FRP) Wrap on Ultimate Load -- 5.2.2 Effect of Fiber Reinforced Polymer (FRP) Wrap on Secant Stiffness -- 5.2.3 Effect of Fiber Reinforced Polymer (FRP) Wrap on Ductility Index (DI) -- 5.3 Repair of Fire-Damaged Concrete-Filled Double Skin Steel Tubular (CFDST) Column with Hybrid Fiber Reinforced Polymer (FRP) -- References -- 6 Conclusion and Recommendation -- 6.1 Relationship Between Thickness of Outer Steel Tube and Maximum Temperature of Concrete -- 6.2 Residual Strength of Concrete-Filled Double Skin Steel Tubular (CFDST) Columns After Fire Exposure -- 6.3 Effectiveness of Repair Method Using Single and Hybrid Fiber Reinforced Polymer (FRP) on Fire-Damaged Concrete-Filled Double Skin Steel Tubular (CFDST) Columns -- 6.4 Recommendation for Future Work -- Reference. 330 $aThis book highlights the residual strength of the CFDST column, that can be used to determine the most suitable repair method in order to retrofit the column. This book also discusses the effectiveness of repair method using single and Hybrid Fibre Reinforced Polymer (FRP) of fire-damaged CFDST columns. 410 0$aSpringerBriefs in applied sciences and technology. 606 $aFire prevention 606 $aColumns, Iron and steel$xFires and fire prevention 606 $aConcrete construction$xFires and fire prevention 615 0$aFire prevention. 615 0$aColumns, Iron and steel$xFires and fire prevention. 615 0$aConcrete construction$xFires and fire prevention. 676 $a363.3 700 $aChoong$b Kok Keong$0995777 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9910491028603321 996 $aConcrete-filled double skin steel tubular column with hybrid fibre reinforced polymer$92816717 997 $aUNINA