LEADER 05206nam 2200601 a 450 001 9910456221403321 005 20200520144314.0 010 $a0-7844-7320-X 035 $a(CKB)2480000000004950 035 $a(EBL)3115482 035 $a(SSID)ssj0000630677 035 $a(PQKBManifestationID)12254450 035 $a(PQKBTitleCode)TC0000630677 035 $a(PQKBWorkID)10747670 035 $a(PQKB)10129992 035 $a(MiAaPQ)EBC3115482 035 $a(Au-PeEL)EBL3115482 035 $a(CaPaEBR)ebr10467706 035 $a(OCoLC)732956542 035 $a(EXLCZ)992480000000004950 100 $a20110516d2010 uy 0 101 0 $aeng 135 $aur|n|---||||| 181 $ctxt 182 $cc 183 $acr 200 10$aElectrical transmission and substation structures$b[electronic resource] $etechnology for the next generation : proceedings of the 2009 Electrical Transmission and Substation Structures Conference, November 8-12, 2009 Fort Worth, Texas /$fsponsored by Electrical Transmission Structures Committee of the Structural Engineering Institute (SEI) of the American Society of Civil Engineers ; edited by Marlon W. Vogt 210 $aReston, Va. $cAmerican Society of Civil Engineers$d2010 215 $a1 online resource (531 p.) 300 $aDescription based upon print version of record. 311 $a0-7844-1077-1 320 $aIncludes bibliographical references and index. 327 $a""Cover""; ""Table of Contents""; ""Loading I""; ""Are Wood Poles Getting Weaker?""; ""The Chaotic Confusion Surrounding a???Wood Equivalenta??? Non-Wood Poles""; ""Estimation of Containment Loads on a 230kV Steel Transmission Line Using Finite Element Model""; ""Common Sag and Tension Errors: Ita???s Time for Template Technology to be Put in the Drawer Forever""; ""Analysis and Design I""; ""Laboratory and Field Testing of Steel Davit Arm Fatigue Failures on Concrete Poles""; ""Lessons Learned from Design and Test of Latticed Steel Transmission Towers""; ""Lessons Learned on Mega Projects"" 327 $a""345 kV High Ampacity OH/UG Project""""Foundations""; ""Integration of Optimum, High Voltage Transmission Line Foundations""; ""Geotechnical Investigations for a Transmission Line Are More Than Drilled Borings""; ""Transmission Pole Foundations: Alternate Design Methods for Direct-Embedded Round, Wood Transmission Poles""; ""Assessment and Repair of Steel Tower and Steel Pole Foundations""; ""Substation Design""; ""Substation Bus Design: Current Methods Compared with Field Results""; ""3D Automated Design of Substations""; ""Seismic Design of Substation Structures"" 327 $a""Analytical Techniques to Reduce Magnetic Force from High Fault Current on Rigid Bus""""Loading II""; ""Wind Loading: Uncertainties and Honesty Suggest Simplification""; ""Review of Span and Gust Factors for Transmission Line Design""; ""Wind Load Methodologies for Transmission Line Towers and Conductors""; ""The Effects of Ice Shedding on a 500 kV Line""; ""Analysis and Design II""; ""Fact or Fictiona???Weathering Steel Can Provide Effective Corrosion Protection to Steel Structures""; ""Large Catenary Structures for High Voltage Transmission Lines"" 327 $a""Aesthetic Mitigationa???The Challenge Confronting Future Expansion of Transmission Lines""""Alabama Power Increases Line Capacity Using 3M ACCR Conductor (On Existing Towers)""; ""Case Studiesa???Foundations""; ""Golden Pass LNG 230kV Double Circuit: Foundations""; ""Deepwater Transmission Line Foundations Meet Trophy Bass Lake Environment""; ""230kV Lattice Tower Replacement: An Example of Design Loading Not Addressed in the NESC""; ""Design and Construction Challenges of Overhead Transmission Line Foundations (NUa???s Middletown Norwalk Project)""; ""Case Studiesa???Construction Challenges"" 327 $a""Transmission Line Construction in Sub-Arctic Alaska Case Study: a???Golden Valley Electric Associationa???s 230kV Northern Intertiea???""""The 2008 Iowa Floods: Structural Challenges and Solutions""; ""Transmission Line at St. Andrew Bay""; ""Construction Challenges of Extra High Voltage Transmission Lines: Building in the Most Difficult Terrain in the World""; ""Applied Technologies""; ""Vegetation Management Through LiDAR Derived CADD Models: Compliance with NERC Reliability Standard FAC-003-1""; ""Sequential Mechanical Testing of Conductor Designs"" 327 $a""H2S Entrapment and Corrosion on Direct Embedded Galvanized Steel Transmission Poles"" 606 $aElectric lines$xPoles and towers$xDesign and construction$vCongresses 606 $aStructural engineering$vCongresses 608 $aElectronic books. 615 0$aElectric lines$xPoles and towers$xDesign and construction 615 0$aStructural engineering 676 $a621.31922 701 $aVogt$b Marlon W$0982439 712 02$aAmerican Society of Civil Engineers.$bCommittee on Electrical Transmission Structures. 801 0$bMiAaPQ 801 1$bMiAaPQ 801 2$bMiAaPQ 906 $aBOOK 912 $a9910456221403321 996 $aElectrical transmission and substation structures$92242280 997 $aUNINA