01917nam 2200409I 450 991070614610332120170906100322.0(CKB)5470000002454967(OCoLC)1002926324(EXLCZ)99547000000245496720170906j200101 ua 0engur|||||||||||txtrdacontentcrdamediacrrdacarrierAssessment of RELAP5/MOD3.2-NPA3.4 against an inadvertent closure of all three MSIV's in VANDELLOS-II Nuclear Power Plant /prepared by C. Llopis, A. Tanarro, R.M. FanegasWashington, DC :Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission,January 2001.1 online resource (x, 61 pages) illustrationsInternational agreement report ;NUREG/IA-0197"TECNATOM.""January 2001.""Prepared as part of the Agreement on Research Participation and Technical Exchange under the International Code Application and Maintenance Program (CAMP).""Sponsoring organization: Division of Systems Analysis and Regulatory Effectiveness, Office of Nuclear Regulatory Research, U.S. Nuclear Regulatory Commission"--Bibliographic data sheet.Assessment of RELAP5/MOD3.2 NPA3.4 against an inadvertent closure of all three MSIV's in VANDELLOS-II Nuclear Power PlantPressurized water reactorsAccidentsSpainComputer simulationPressurized water reactorsAccidentsComputer simulation.Llopis C.1405972Tannaro A.Fanegas R. M.U.S. Nuclear Regulatory Commission.Office of Nuclear Regulatory Research,GPOGPOBOOK9910706146103321Assessment of RELAP53483636UNINA