01860nam 2200325 n 450 991052020970332120231215145104.01-5044-8000-7(CKB)5600000000432758(NjHacI)995600000000432758(EXLCZ)99560000000043275820231215d2022 uy 0engur|||||||||||txtrdacontentcrdamediacrrdacarrier184_1017.2-2021 - IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation /Institute of Electrical and Electronics EngineersNew York, USA :IEEE,2022.1 online resource (44 pages)Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or metallic barrier, and armor or encapsulating material. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or metallic barrier cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.Electric cablesCongressesElectric cables621.31934NjHacINjHaclDOCUMENT9910520209703321184_1017.2-2021 - IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation3652164UNINA