01830nam 2200373 450 991013590110332120231207080910.01-55937-193-510.1109/IEEESTD.1992.106968(CKB)3780000000089921(NjHacI)993780000000089921(EXLCZ)99378000000008992120231207d1992 uy 0engur|||||||||||txtrdacontentcrdamediacrrdacarrierIEEE Std 1018-1991 IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber Insulation /Institute of Electrical and Electronics EngineersNew York, NY, USA :IEEE,1992.1 online resource (27 pages) illustrationsIn this standard minimum requirements for the construction, manufacturing, purchasing, and application of electric submersible pump cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, and armor, and is rated for voltages not exceeding 3 kV or 5kV and for ambient temperatures not exceeding 284 degrees F. Conductors, insulation, barrier (optional), assembly and jacket, armor, requirements for testing by the manufacturer, and cable ampacity are covered.IEEE Std 1018-1991: IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber InsulationElectric cablesInsulationElectric cablesTestingElectric cablesInsulation.Electric cablesTesting.621.31934NjHacINjHaclDOCUMENT9910135901103321IEEE Std 1018-19912573544UNINA