02011nam 2200409 450 991013528110332120231208073805.00-7381-9118-310.1109/IEEESTD.2014.6840837(CKB)3780000000092075(NjHacI)993780000000092075(EXLCZ)99378000000009207520231208d2014 uy 0engur|||||||||||txtrdacontentcrdamediacrrdacarrierANSI N323AB-2013 (Revision and Redesignation of ANSI N323A-1997 and ANSI N323B-2002) American National Standard for Radiation Protection Instrumentation Test and Calibration, Portable Survey Instruments /Institute of Electrical and Electronics EngineersNew York, NY, USA :IEEE,2014.1 online resource (ix, 30 pages) illustrationsIEEE StdTesting, calibration, and calibration frequency requirements for portable radiation detectors used to directly measure alpha, beta, photon, and neutron radiation are defined. Also defined are the calibration and testing requirements for alpha and beta-gamma measurements of surface contamination levels using portable radiation detectors. Portable radiation detectors may be battery or line powered.IEEE Std.ANSI N323AB-2013 (Revision and Redesignation of ANSI N323A-1997 and ANSI N323B-2002): American National Standard for Radiation Protection Instrumentation Test and Calibration, Portable Survey InstrumentsANSI N323AB-2013 RadioactivityMeasurementSurveyingInstrumentsRadioactivityMeasurement.SurveyingInstruments.539.752NjHacINjHaclDOCUMENT9910135281103321ANSI N323AB-2013 (Revision and Redesignation of ANSI N323A-1997 and ANSI N323B-2002)2577151UNINA