1.

Record Nr.

UNISA996280735203316

Titolo

IEEE Std 1310-2012 (Revision of IEEE Std 1310-1996) - Redline : IEEE Recommended Practice for Thermal Cycle Testing of Form-Wound Stator Bars and Coils for Large Rotating Machines - Redline / / IEEE

Pubbl/distr/stampa

New York, NY, USA : , : IEEE, , 2012

ISBN

0-7381-7568-4

Descrizione fisica

1 online resource (58 pages)

Disciplina

543.086

Soggetti

Thermal analysis

Lingua di pubblicazione

Inglese

Formato

Materiale a stampa

Livello bibliografico

Monografia

Sommario/riassunto

This procedure is intended for form-wound bars/coils for rotating machines rated 10 kV or more at 50 Hz or 60 Hz that are subjected to many transitions from no-load to full-load current during normal operations, and where rapid load variations are typical. Only the thermal cyclic degradation within the groundwall insulation and/or the conductor package and delamination of the groundwall insulation from the conductor are addressed by this test. The procedure is applicable to indirectly-cooled machine types such as: (1) combustion turbine generators (2) pumped storage or peaking duty hydrogenerators (3) synchronous condensers (4) cyclic duty water pump motors. Various pass/fail criteria are presented, and the ones that apply in a specific circumstance must be agreed between user and manufacturer prior to commencement of testing.