1.

Record Nr.

UNINA9910480722603321

Autore

Sauve Claude

Titolo

L'interview à la radio et à la télévision / / Claude Sauvé

Pubbl/distr/stampa

[Montreal, Quebećbec] : , : Les Presses de I'Universite de Montreal, , 2009

©2009

ISBN

2-7606-3063-3

979-1-03-650216-3

2-7606-2563-X

Descrizione fisica

1 online resource (245 p.)

Collana

Paramètres

Disciplina

070.4/3

Soggetti

Interviewing on radio

Interviewing on television

Interviewing in mass media

Lingua di pubblicazione

Francese

Formato

Materiale a stampa

Livello bibliografico

Monografia

Note generali

Publ. antérieurement sous le titre: Faire dire. 2000.

Nota di bibliografia

Includes bibliographical references and index.

Nota di contenuto

Les concepts et la méthode -- Le sujet et l'angle de traitement -- Les trois types d'interview -- La recherche -- La préinterview -- L'interview proprement dite -- Le contexte -- La suite de l'interview -- Conclusion.

Sommario/riassunto

N'importe qui – à condition d'avoir du talent et un peu d'instinct – peut interroger une autre personne dans le but de diffuser une information. Mais si l'on fait de l'interview son métier, connaître les règles et les techniques fait la différence entre l'échec et la réussite.  Ce livre s'adresse aux intervieweurs comme aux interviewés, aux professionnels comme aux étudiants, bref à tous ceux et celles qui entretiennent des liens avec les médias et l'information. Il expose des concepts et des procédés permettant de comprendre les mécanismes de l'interview à toutes ses étapes, de la recherche jusqu'à la conclusion. Intervieweur chevronné, Claude Sauvé illustre son propos d'exemples réels, tirés d'émissions d'information récentes, et tient compte des moyens les plus avancés du monde des communications.



2.

Record Nr.

UNINA9910822370003321

Titolo

Ultra-high performance liquid chromatography and its applications / / edited by Quanyun Alan Xu

Pubbl/distr/stampa

Hoboken, N.J., : John Wiley & Sons Inc., 2013

ISBN

9781118533987

1118533984

9781118533956

111853395X

9781299464940

1299464947

9781118533994

1118533992

Edizione

[1st ed.]

Descrizione fisica

1 online resource (306 p.)

Classificazione

TEC009010

Altri autori (Persone)

XuQuanyun A. <1961->

Disciplina

543/.84

Soggetti

Liquid chromatography

Lingua di pubblicazione

Inglese

Formato

Materiale a stampa

Livello bibliografico

Monografia

Note generali

Description based upon print version of record.

Nota di bibliografia

Includes bibliographical references and index.

Nota di contenuto

Ultra-High Performance Liquid Chromatography and Its Applications; Contents; Preface; Contributors; Chapter 1 UHPLC Method Development; 1.1 INTRODUCTION; 1.2 METHOD DEVELOPMENT; 1.2.1 Gather Sample Information and Define Method Goals; 1.2.2 Scout Columns and Mobile Phases; 1.2.3 Analyze Scouting Results and Select Separation Conditions; 1.2.4 Optimize the Method; 1.2.5 Validate the Method; 1.2.6 Phase-Appropriate Method Development; 1.2.7 Very High Pressure and Frictional Heating in UHPLC; 1.2.8 Relevance of Various Instrumentation to Method Development

1.2.9 Method Resolution and Speed Requirements1.2.10 Example 1.1; 1.2.11 Example 1.2; 1.3 CONVERSION OF AN HPLC METHOD TO UHPLC; 1.3.1 Select a UHPLC Column with the Same Chemistry; 1.3.2 Measure Dwell Volumes of HPLC and UHPLC Systems; 1.3.3 Calculate Injection Volume, Flow Rate, Holding Time, and Gradient Segment Time; 1.3.4 Perform Verification Experiment; 1.3.5 Validate the Method; 1.3.6 Example 1.3; 1.3.7 Example 1.4; 1.4 CONVERSION OF A UHPLC



METHOD TO HPLC; 1.5 SUMMARY; REFERENCES; Chapter 2 Method Transfer Between HPLC and UHPLC Platforms; 2.1 INTRODUCTION

2.2 TRANSFERRING HPLC METHODS TO UHPLC2.2.1 Fundamental Physical Relationships; 2.2.2 Types of UHPLC Applications; 2.2.3 Additional Fundamental Considerations; 2.2.4 Transfer of Isocratic Methods from HPLC to UHPLC; 2.2.5 Cautions on Transferring Isocratic Methods from HPLC to UHPLC; 2.2.6 Transfer of Gradient Methods from HPLC to UHPLC; 2.2.7 Cautions on the Scaling of Gradient Methods from HPLC to UHPLC; 2.2.8 Case Studies and Recommendations; 2.2.9 Final Discussion of Practical Challenges; 2.2.10 Conclusions on the Transfer of Methods from HPLC to UHPLC

2.3 TRANSFERRING UHPLC METHODS TO HPLC PLATFORMS2.3.1 UHPLC to Traditional HPLC Columns; 2.3.2 UHPLC to Superficially Porous Particle HPLC Columns; 2.3.3 UHPLC to HPLC Method Transfer; 2.4 TRANSFERRING LC METHODS TO OTHER LABS; 2.4.1 UHPLC Instrument Issues Encountered During Method Transfers; 2.4.2 Back to LC Basics; REFERENCES; Chapter 3 Practical Aspects of Ultrahigh Performance Liquid Chromatography; 3.1 INTRODUCTION; 3.2 EFFECT OF EXTRA-COLUMN VOLUME ON PERFORMANCE OF SUB-2 lM PARTICLE-PACKED COLUMNS IN UHPLC; 3.2.1 Theoretical Considerations

3.2.2 Extra-Column Volumes and Column Volumes3.2.3 Effect of Extra-Column Volume on Performance; 3.3 COLUMN PRESSURE AND FRICTIONAL HEATING; 3.3.1 Column Pressure vs. Particle Size; 3.3.2 Phenomenon of Frictional Heating; 3.3.3 Effect of Frictional Heating on Retention Factor; 3.3.4 Factors Leading to Frictional Heating; 3.3.5 How to Resolve Thermal Gradient Issues; 3.3.6 Effect of Pressure on Mobile Phase Characteristics; 3.3.7 Effect of Pressure on Retention Factor with Minimal Frictional Heating; 3.4 METHOD TRANSFER BETWEEN UHPLC AND HPLC AND OTHER TIPS

3.4.1 Column Dimension and Particle Size

Sommario/riassunto

"This is the first resource to fully cover the instrumentation, method development, and applications of Ultra-High Performance Liquid Chromatography (U-HPLC). It details both the benefits and limitations of this method in the pharmaceutical industry, clinical research, the food industry, and environmental services. It covers U-HPLC topics coupled with ultra-violet detector (UV) and mass spectrometer (MS), instrumentation frequently used in solving complex molecules. This is an essential reference for scientists who utilize chromatographic techniques, including in academia, as well as pharmaceutical, biotechnology, chemical, food, environmental, and related industries"--