IEEE Std 1018-1985 : IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Ethylene-Propylene Rubber Insulation / / Institute of Electrical and Electronics Engineers
Pubbl/distr/stampa
New York, NY, USA : , : IEEE, , 1984
ISBN
0-7381-4317-0
Descrizione fisica
1 online resource (12 pages)
Disciplina
621.31934
Soggetti
Electric cables - Insulation
Electric cables - Testing
Lingua di pubblicazione
Inglese
Formato
Materiale a stampa
Livello bibliografico
Monografia
Sommario/riassunto
This recommended practice establishes requirements for a three-conductor round-type oil-well cable used in supplying three-phase ac electric power to submersible pump motors. Cables meeting the requirements of the recommended practice shall be rated for voltages not exceeding 3 kV or 5 kV and for ambient temperatures not exceeding 257 F (125 C). Use of cable above rated temperature can cause premature deterioration of the insulation. Voltage ratings are nominal phase-to-phase ratings.